RC1: 'Comment on egusphere-2025-4855', Akli Benali, 24 Feb 2026
- CC1: 'Reply on RC1', Jean-Baptiste Filippi, 08 Mar 2026
- AC1: 'Reply on RC1', Alberto Alonso Pinar, 26 Apr 2026
-
RC2: 'Comment on egusphere-2025-4855', Anonymous Referee #2, 23 Mar 2026
- AC2: 'Reply on RC2', Alberto Alonso Pinar, 26 Apr 2026
Peer review completion
AR – Author's response | RR – Referee report | ED – Editor decision | EF – Editorial file upload
ED: Reconsider after major revisions (further review by editor and referees) (27 Apr 2026) by Ricardo Trigo
AR by Alberto Alonso Pinar on behalf of the Authors (27 Apr 2026)
Author's response
Author's tracked changes
Manuscript
ED: Referee Nomination & Report Request started (12 May 2026) by Ricardo Trigo
RR by Anonymous Referee #2 (08 Jun 2026)
ED: Publish as is (09 Nov 2026) by Ricardo Trigo
AR by Alberto Alonso Pinar on behalf of the Authors (11 Nov 2026)
Manuscript
Post-review adjustments
AA – Author's adjustment | EA – Editor approval
AA by Alberto Alonso Pinar on behalf of the Authors (20 Nov 2026)
Author's adjustment
Manuscript
EA: Adjustments approved (23 Nov 2026) by Ricardo Trigo
The paper shows the implementation of simplified Eulerian-based spotting model over two distinct cases: 1) "synthetic" case studies 2) real case study. The paper needs substancial reviews to ensure it provides a solid contribution. At this stage there is some confusion and the objetives and associated workflow need to be clarified.
Main Comments
Please revise both aspects so that it is clear to the reader what is intended in each step of the analysis. Verify is not the best term. Use evaluate\assess in the first case, validate in the second.
Minor Comments:
- Check Reference formatting. Example (L34): “offered by (Sullivan, 2009))” as opposed to “offered by Sullivan (2009),”.
- What do you mean by “all six degrees of freedom”? L55
- L56…references…
- L70: it does not make sense to say that it spans from grassland to very large fires. Maybe grassland and shrub-forest fires or small to very large fires. Grassland fires can be large fires.
- Methods described what “was” done (L104). Change the remaning text accordingly.
- Equation 1: not all terms are described. Correct “C_i” to match the equation.
- L174: kW.m-2
- L178: looks like this sentence is repeated.
- Don’t understand this sentence “The Mt Bolton namefiles are published accompanying the MesoNH-ForeFire repository as an open-source dataset.”
- L194: “During this phase, the fuel supported intense short range (less than 1 km) spotting”, to avoid discussions around the importance of fuel, I suggest you simply state that intense short range spotting occurred.
- Suggest moving the paragraph in L200 to the top.
- L210: what was the extent (in ha) of the Mt Bolton fire? Move this paragraph upwards, it is generic information about the fire which contrasts with specific information, for example, regarding plume measurements.
- L216-17: repeated.
- Figure 2 shows before it is mentioned
- L307: “had already shifted”
- Figure 4: larger numbers on the axis. What is “Wind Y”? Never mentioned before. What are the units?
- L185: rephrase the last sentence to make it clearer.
- First 2 paragraphs of 3.2.4: Methods. Also part of the 3rd paragraph
- L452: do you mean “slope”?
- L454: I don’t think your results allow you to state “including the topography in a spotting model would enhance its overall accuracy.” You could do that, if you run Mt Bolton Fire without topography, compared the results and concluded that accuracy was higher when topography was used.
- L455: Make it clear that you are making the transition from the idealized cases to the Mt Bolton fire.
- L458-460: also short distance spotting can be rapidly absorbed by the fire front without being detected. In the first hours your highest “mass deposition” values are close to the fire front.
- L499: I believe the term is “new ignitions” and not “reignition”
- L539: “radar”
- L542: rewrite sentence “consistent advection field in which to embed firebrand transport”
- L544 “with observations”