<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">NHESS</journal-id><journal-title-group>
    <journal-title>Natural Hazards and Earth System Sciences</journal-title>
    <abbrev-journal-title abbrev-type="publisher">NHESS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Nat. Hazards Earth Syst. Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1684-9981</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/nhess-19-1365-2019</article-id><title-group><article-title>From rapid visual survey to multi-hazard risk prioritisation and numerical
fragility of school buildings</article-title><alt-title>From rapid visual survey to multi-hazard risk prioritisation</alt-title>
      </title-group><?xmltex \runningtitle{From rapid visual survey to multi-hazard risk prioritisation}?><?xmltex \runningauthor{R.~Gentile et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Gentile</surname><given-names>Roberto</given-names></name>
          <email>r.gentile@ucl.ac.uk</email>
        <ext-link>https://orcid.org/0000-0002-7682-4490</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Galasso</surname><given-names>Carmine</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-5445-4911</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Idris</surname><given-names>Yunita</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Rusydy</surname><given-names>Ibnu</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Meilianda</surname><given-names>Ella</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Institute for Risk and Disaster Reduction, University College London,
London, UK</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Department of Civil, Environmental and Geomatic Engineering,
University College London, London, UK</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Tsunami and Disaster Mitigation Research Center (TDMRC), Universitas
Syiah Kuala, Banda Aceh, Indonesia</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Roberto Gentile (r.gentile@ucl.ac.uk)</corresp></author-notes><pub-date><day>11</day><month>July</month><year>2019</year></pub-date>
      
      <volume>19</volume>
      <issue>7</issue>
      <fpage>1365</fpage><lpage>1386</lpage>
      <history>
        <date date-type="received"><day>22</day><month>December</month><year>2018</year></date>
           <date date-type="rev-request"><day>15</day><month>January</month><year>2019</year></date>
           <date date-type="rev-recd"><day>9</day><month>May</month><year>2019</year></date>
           <date date-type="accepted"><day>21</day><month>May</month><year>2019</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2019 </copyright-statement>
        <copyright-year>2019</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://nhess.copernicus.org/articles/.html">This article is available from https://nhess.copernicus.org/articles/.html</self-uri><self-uri xlink:href="https://nhess.copernicus.org/articles/.pdf">The full text article is available as a PDF file from https://nhess.copernicus.org/articles/.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e130">Regional seismic risk assessment is paramount in
earthquake-prone areas, for instance, to define and implement prioritisation
schemes for earthquake risk reduction. As part of the Indonesia School Programme to Increase Resilience (INSPIRE), this paper
proposes an ad hoc rapid-visual-survey form, allowing one to (1) calculate the
newly proposed INSPIRE seismic risk prioritisation index, which is an
empirical proxy for the relative seismic risk of reinforced concrete (RC)
buildings within a given building portfolio; (2) calculate the Papathoma
Tsunami Vulnerability Assessment (PTVA) index, in any of its variations; (3) define one or more archetype buildings representative of the analysed
portfolio; (4) derive detailed numerical models of the archetype buildings,
provided that the simulated design is used to cross-check the model assumptions.
The proposed INSPIRE index combines a baseline score, calibrated based on
fragility curves, and a performance modifier, calibrated through the
analytic hierarchy process (AHP) to minimise subjectivity. An attempt to
define a multi-hazard prioritisation scheme is proposed, combining the
INSPIRE and PTVA indices. Such a multi-level framework is implemented for 85
RC school buildings in Banda Aceh, Indonesia, the most affected city by
the 2004 Indian Ocean earthquake–tsunami sequence. As part of the proposed
framework, two archetype buildings representative of the entire portfolio
are defined based on the collected data. Their seismic performance is
analysed by means of non-linear static analyses, using both the analytical
simple lateral mechanism analysis (SLaMA) method and numerical finite-element pushover analyses to investigate the expected plastic mechanisms and
derive displacement/drift thresholds to define appropriate damage states.
Finally, non-linear dynamic analyses are performed to derive fragility
curves for the archetype buildings. This paper demonstrates the
effectiveness of the INSPIRE data collection form and proposed index in
providing a rational method to derive seismic risk prioritisation schemes
and in allowing the definition of archetype buildings for more detailed
evaluations/analyses.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

      <?xmltex \hack{\allowdisplaybreaks}?>
<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e144">Regional seismic risk assessment is paramount in highly earthquake-prone
areas. In fact, in several countries around the world, a large portion of
the building stock has been designed and/or constructed according to obsolete
structural codes, which include little-to-no provisions for earthquake
resistance and detailing. Several reinforced concrete (RC) buildings fall in
this category, and they often represent the highest share for both
residential and commercial occupancy in many countries (e.g. in Italy
48 % of the buildings constructed after 1971 are made of RC; ISTAT 2011).
RC structural systems are also widely used in the design of critical
infrastructure, such as hospitals and school facilities. Those are the focus
of this paper. Clearly, it is desirable that any risk-mitigation strategy
designed by governmental agencies should be based on a rational
understanding of the risk of large building groups – or portfolios – at a
country level (or in a smaller region). However, it is cost-ineffective to
perform detailed structural simulations for a large amount of structures,
given the shortage of both financial and technical and/or computational resources.
Therefore, a multi-level<?pagebreak page1366?> approach is usually preferred, starting with a
screening based on simplified and rapid methods and performing more detailed
structural analyses only for selected groups of structures at higher
relative risk and for which an archetype (or index) building can be
identified (e.g. FEMA P-154, 2015; Benedetti and Petrini, 1984; Grant et
al., 2007).</p>
      <p id="d1e147">Common approaches for regional seismic risk assessment of RC buildings (see
Sect. 2 for more details) refer to typological
approaches based on predetermined building categories (e.g. Giovinazzi
and Lagomarsino, 2004) or the use of rapid-visual-survey (RVS) forms
and calibrated empirical seismic vulnerability/risk indices (e.g. Uva et al., 2016). Although these approaches rely on various assumptions, such simplified methods provide valuable proxies to develop prioritisation schemes (i.e. performing a ranking of the buildings in a given portfolio based on their relative vulnerability or risk-related metrics). As discussed, such simplified methods include some degree of subjectivity by the analyst, mainly reflected in the choice and the assigned relative importance of the parameters involved in the analysis. Moreover, given the low amount of information required, such methods do not allow one to further refine the analysis, providing a more detailed, second-level seismic risk assessment. Finally, those methods mostly refer to seismic hazard, which in some countries might not be enough for the development of a rational multi-hazard prioritisation scheme.</p>
      <p id="d1e150">Numerous evidences of previous natural-hazard events have highlighted the
vulnerability of school infrastructure to natural hazards and particularly
to earthquake-induced ground shaking. From the structural and architectural
points of view, school buildings are especially vulnerable given structural
characteristics that typically include large rooms, large windows
(particularly in tropical climates), and corridors, all of which may
represent seismic vulnerability factors. At the same time, schools play a
critical role in the education of a community's next generation, with school
children being one of the most vulnerable components of the society due to
their age and their developmental stage. A safer and resilient school can
save valuable lives of children and help to bring normality back to society
in times of disaster. These considerations set school buildings apart from
their peers in terms of priority for assessment and resource allocation for
structural retrofitting. In fact, some of the world disaster reduction
campaigns by the United Nations International Strategy for Disaster
Reduction (UNISDR) were carried out together with various partner
organisations under the theme of “Disaster Risk Reduction Begins at
School” (UNCRD, 2009). Recently, the Comprehensive School Safety Framework
(CSSF; GADRRRES, 2017) has proposed an integrated approach to reduce
disaster risk and promote resilience in the education sector. The CSSF is
funded on three pillars: “Safe Learning Facilities” (including “implementing assessment and prioritisation plans for retrofitting or replacing unsafe schools, including relocation”), “School Disaster Management” and “Risk Reduction and Resilience Education”.</p>
      <p id="d1e153">Based on the above discussion, a new RVS form and a seismic risk
prioritisation index for RC buildings are proposed in this study to address
the above-mentioned gaps. Both the RVS form and the seismic index are the
first outcomes of the INSPIRE project (Indonesia School Programme to Increase Resilience). INSPIRE looks to develop an
advanced, harmonised and science-based risk assessment framework for school
infrastructure in Indonesia subjected to cascading earthquake–tsunami
hazards. It also assesses the effectiveness of different soft (e.g. risk-reduction education) and hard (e.g. structural retrofitting) mitigation measures in
reducing casualties, economic loss and disruption to school infrastructure,
thus increasing community resilience.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e159">INSPIRE rapid-visual-survey form completed for a building with ID 14A (Sect. 4.1).</p></caption>
        <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f01.png"/>

      </fig>

      <p id="d1e168">The INSPIRE RVS form (Fig. 1) is designed to be
completed by trained engineers in approximately 20–30 min – depending on
the size of the building – by means of a sidewalk survey. This is a one-page
form including various sections related to the general identification and
geolocation of the building, its geometric properties (including space for
sketching the building's shape and footprint), and its structural
characteristics and deficiencies, including the structural typology and the
details of the main structural members. It is also possible to
assign a confidence level for each parameter, allowing for a better
classification and weighting of the data after a campaign of RVSs. The back
of the form is used to provide definition of both the parameters and the
confidence levels and provides a blank space that can be used to register extra
information. The collected data are fully compatible with both the Global
Earthquake Model (GEM) Building Taxonomy (Brzev et al., 2013) and the Hazard
United States (HAZUS) model (Kircher et al., 2006). The collected
information allows one to (1) calculate the proposed INSPIRE seismic risk
prioritisation index, introduced in  Sect. 3; (2) calculate the Papathoma Tsunami Vulnerability Assessment index (PTVA4, Dall'Osso et al., 2016, in any of its variations, described in Sect. 4.2); (3) define one or more representative archetype buildings consistent with the local building codes and practice; and (4) derive detailed numerical models of the archetype buildings, provided that the simulated design is used to cross-check the model assumptions. The unique features of the INSPIRE form include (1) the possibility of considering both seismic and tsunami hazards while requiring a reasonable amount of time to complete the survey; (2) the consideration of confidence levels for the parameters, which is particularly useful in deriving statistics; and (3) the possibility to be expanded to include other hazards with simple modifications/customisations.</p>
      <p id="d1e171">In particular, the INSPIRE seismic risk prioritisation index (Sect. 3) aims at providing a simple method to derive a prioritisation scheme, minimising the subjectivity involved in the calculation. In fact, mechanics-based fragility functions are used to define a baseline score. A performance modifier is defined based on parameters that can jeopardise the seismic<?pagebreak page1367?> performance of a building (e.g. presence of short columns, pounding potential). The weight assigned to each parameter is defined through the analytic hierarchy process (AHP; Saaty, 1980), providing a mathematically consistent and rational solution to the weighting process.</p>
      <p id="d1e174">In this study, the INSPIRE RVS form and proposed multi-hazard risk
prioritisation index are applied to a portfolio of 85 RC school buildings in
Banda Aceh, Indonesia, highlighting the simplicity and rapidity of the whole
process. Moreover, consistently with the proposed multi-level framework, a
detailed analytical and numerical seismic fragility assessment is provided
for the identified archetype school building, demonstrating the
effectiveness of the INSPIRE RVS form in providing inputs and allowing more
detailed analyses.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Seismic risk prioritisation schemes: a review</title>
      <p id="d1e185">Various methodologies to derive prioritisation schemes for buildings based
on their relative seismic vulnerability/risk are available in the scientific
literature and or international standards/guidelines. Each of these is
characterised by a different underlying approach, basic assumptions and/or
applicability conditions. Most of these are based on the calculation of a
seismic vulnerability/risk index for a portfolio of buildings. The results
can be used to rank those buildings, defining a priority list of structures
requiring further investigation. A comprehensive overview of this previous
research is not within the scope of this paper; however, a briefing of some
relevant past initiatives is presented here.</p>
      <p id="d1e188">The procedure proposed in the guidelines by the Applied Technology Council
(ATC 3-06, 1978) uses a strength-based approach to define an earthquake
capacity ratio, comparing the actual strength of the building to the code
requirement for new ones. Adjustments are also adopted to consider in situ
material properties and insufficient detailing (compared to modern design).
Such a capacity-to-demand ratio is defined as the earthquake capacity ratio,
and it is calculated as the minimum of the component-by-component strength
ratios.</p>
      <p id="d1e191">The Alaska's Department of Education (1997), among others, has produced
surveying forms to assess the structural conditions of buildings and the
associated seismic<?pagebreak page1368?> vulnerability, with focus on school buildings. Such forms
mainly consist of checklists investigating areas of potential concerns for
seismic vulnerability. On the other hand, the procedure introduced by the
Federal Emergency Management Agency (FEMA P-154, 2015) is based on a rapid
visual screening of buildings and a two-level approach for a fast assignment
of a seismic vulnerability index (which requires no mechanical calculation
from the user). The companion FEMA P-155 (2015) describes the rationale
behind the scoring system, which is directly connected to the probability of
collapse of archetype building categories. Such a method is based on the HAZUS
framework (and typological force-displacement curves) to define the building
categories and to derive a seismic-only assessment.</p>
      <p id="d1e194">The New Zealand Society for Earthquake Engineering (NZSEE) defines an
initial evaluation procedure (IEP) in the NZSEE guidelines of 2017,
providing a broad indication of the seismic rating of a building based
on a sidewalk survey. The score is expressed in terms of the percentage of
the new building standard (%NBS), which is the ratio of the displacement
capacity of the building for the life safety limit state over the minimum
capacity required for a new building for the same limit state. Firstly, a
baseline %NBS is calculated using specifically tabulated coefficients
relating to year of design, strengthening interventions, importance of the
structure, assumed ductility capacity, site hazard, presence of near-fault
effects, soil type, etc. It is assumed that the capacity of the building
cannot be lower than the minimum specified by the code valid for the year of
design. This is only true if building codes are legally enforced. If this is
not the case, the seismic vulnerability assessment may be characterised by a
higher level of epistemic uncertainty. The baseline value is reduced if
structural weaknesses are present (e.g. pounding potential, soil
characteristics, presence of vertical and plan irregularity, presence of
short columns).</p>
      <p id="d1e198">The Italian National Group for Earthquake Defence (Gruppo Nazionale per la Difesa dai Terremoti, GNDT) has also provided
a seismic vulnerability index (Benedetti and Petrini, 1984; Angeletti et
al., 1988) based on simple assessment forms including, among other
parameters, the structural material, the typology of the lateral-load-resisting system (LLRS), the quality of the building materials and the
overall construction, and the existing damage level (if any). The
vulnerability index is based on a weighted sum of such parameters and is
defined in the range [0, 100] for masonry and [<inline-formula><mml:math id="M1" display="inline"><mml:mo lspace="0mm">-</mml:mo></mml:math></inline-formula>25, 100] for reinforced
concrete, mostly based on expert opinion. A higher value of the index
indicates a higher seismic vulnerability. Interestingly, the vulnerability
index by GNDT has been correlated with structural damage in past earthquakes
(e.g. Grimaz et al., 1996), allowing one to indirectly calculate
the peak ground acceleration (PGA), which is likely to induce collapse.</p>
      <p id="d1e208">Other rapid surveying forms and rapid procedures have been proposed by
different authorities and organisations, such as the World Health
Organization (WHO) and the United Nations (UN), with special focus on
developing countries. For instance, Dhungel et al. (2012) collected and
assessed the physical condition of 1381 school building units in Nepal. The
data were collected by mobilising the school teachers; school vulnerability,
calculated on the basis on the empirical weightage on different factors
(e.g. structural material, number of storeys, shape of the roof), was used
to estimate the possible damage, casualties and injuries for earthquakes of
different seismic intensities.</p>
      <p id="d1e211">Finally, a broader perspective is provided in the work by Grant et al. (2007),
which proposes a four-level prioritisation framework focused on school
buildings, filtering the buildings with increased level of detail, allowing policy-makers to choose the filtering thresholds based on the available
resources. The idea is to firstly check the code-based demand deficit of the
buildings, comparing the new structural code demand to the code appropriate
for the year of construction, in terms of PGA. For the buildings with a
deficit above a given threshold, the GNDT index is calculated. The buildings
with the highest rating are assessed with a simplified mechanics-based
procedure, and finally the most critical ones are assessed with structural
models providing full details.</p>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Definition of the INSPIRE seismic risk index</title>
      <?pagebreak page1369?><p id="d1e222">The INSPIRE index (<inline-formula><mml:math id="M2" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">V</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) is an empirical proxy for the relative seismic
risk of various buildings within a given building portfolio. The index is
specifically defined for RC buildings, although its definition can be
extended to other building types, and it consists of two parts: the baseline
score (<inline-formula><mml:math id="M3" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">BL</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and a performance modifier (<inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">PM</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), which are
summed up to obtain the final index (Eq. 1). In its
current version, the baseline score is based on the fragility curves
available in the HAZUS MH4 framework (Kircher et al., 2006), which allows one to have a transparent and consistent fragility estimation for a wide range of
structural typologies. HAZUS fragilities are defined by three primary
parameters based on the RC basic structural system (BSS: frame, infilled frame or wall),
building height (low-rise, mid-rise or high-rise) and seismic design
criteria (pre, low, moderate or high code). On the other hand, the
performance modifier is based on the score of the building regarding eight
secondary parameters (preservation condition, plan shape, storey height
uniformity, added storeys, infills at ground storey, short columns,
pounding, unfavourable soil), which, if present, are deemed to jeopardise
the performance of the building. It is worth mentioning that the selection
of the appropriate fragility curves (HAZUS category) for each building in
the portfolio is an expert decision provided by the analyst. However, as
further discussed below, any other type of fragility curves, if deemed
appropriate, can be used to redefine the INSPIRE index according to the
proposed methodology.

              <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M5" display="block"><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">V</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">BL</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">PM</mml:mi></mml:msub></mml:mrow></mml:math></disp-formula></p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Baseline score</title>
      <p id="d1e294">The HAZUS MH4 framework provides, among other information, an extensive set
of fragility curves representing the seismic performance of archetype
buildings which are classified based on four parameters: material (Mat), BSS,
building height and seismic code level (defined according to the Uniform Building Code, UBC, 1994; ICBO, 1994). Adopting the HAZUS fragility database as a reference is
further motivated by the fact that several countries around the world have
adopted seismic provisions which are, to different extents, consistent with
the recommendations of the UBC 1994. For each archetype building category,
four fragility functions are provided in HAZUS, respectively for the slight,
moderate, extensive and complete damage states (DS), or limit states. The
fragility functions are defined as log-normal cumulative distribution
functions, or CDFs (Eq. 2), in terms of different
intensity measures, among which is the peak ground acceleration (PGA). The
curves are defined by a median PGA (<inline-formula><mml:math id="M6" display="inline"><mml:mi mathvariant="italic">μ</mml:mi></mml:math></inline-formula>) and a dispersion term (<inline-formula><mml:math id="M7" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>).
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M8" display="block"><mml:mtable rowspacing="0.2ex" class="aligned" columnspacing="1em" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mstyle class="stylechange" displaystyle="true"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi>P</mml:mi><mml:mfenced open="(" close=")"><mml:mrow><mml:mi mathvariant="normal">DS</mml:mi><mml:mo>≥</mml:mo><mml:mi mathvariant="normal">DSi</mml:mi><mml:mi mathvariant="normal">|</mml:mi><mml:mi mathvariant="normal">Mat</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">BSS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">Code</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">Height</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">PGA</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mstyle class="stylechange" displaystyle="true"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><?xmltex \hspace{5mm}?><mml:mo>=</mml:mo><mml:mi mathvariant="normal">Φ</mml:mi><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="normal">ln</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="normal">PGA</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="italic">μ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi mathvariant="italic">β</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula></p>
      <p id="d1e394">For the scope of this paper, the HAZUS fragility database has been filtered
to consider only the curves related to RC buildings (namely, categories C1,
C2, C3). Moreover, only the fragility curves corresponding to the extensive
damage limit state (DS3) have been considered, which are mainly related to
the life safety performance objective according to modern seismic codes
(e.g.  ASCE 7–10 – ASCE, 2010; Eurocode 8, or EC8 – CEN, 2004; NZSEE, 2017). The selected fragility curves are
reported in Table 1. Details of the involved
parameters are provided in Table 2.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e400">Selected fragility curves from the HAZUS MH4 framework (Kircher et al.,
2006).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">HAZUS</oasis:entry>
         <oasis:entry colname="col2">Code level</oasis:entry>
         <oasis:entry colname="col3">Height</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mi mathvariant="italic">μ</mml:mi><mml:mo>:</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:mi mathvariant="italic">β</mml:mi><mml:mo>:</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">Inter-storey drift</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">basic structural system</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">median PGA (g)</oasis:entry>
         <oasis:entry colname="col5">dispersion</oasis:entry>
         <oasis:entry colname="col6">limit for DS3 (rad)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">C1 concrete</oasis:entry>
         <oasis:entry colname="col2">Pre-code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.21</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.016</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">moment frame</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.26</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.011</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.21</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.008</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Low code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.27</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.020</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.32</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.013</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.27</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.010</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Moderate code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.41</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.023</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.49</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.015</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.41</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.011</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">High code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.70</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.030</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.73</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.020</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">High-rise</oasis:entry>
         <oasis:entry colname="col4">0.62</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.015</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">C2 concrete</oasis:entry>
         <oasis:entry colname="col2">Pre-code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.24</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.016</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">shear wall</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.30</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.011</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.31</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.008</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Low code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.30</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.020</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.38</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.013</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.38</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.010</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Moderate code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.49</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.023</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.55</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.015</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.57</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.011</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">High code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.90</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.030</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.87</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.020</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">High-rise</oasis:entry>
         <oasis:entry colname="col4">0.82</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.015</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">C3 concrete</oasis:entry>
         <oasis:entry colname="col2">Pre-code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.21</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.012</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">infilled frame</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.25</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.008</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.27</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.006</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Low code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">0.26</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.015</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">0.32</oasis:entry>
         <oasis:entry colname="col5">0.64</oasis:entry>
         <oasis:entry colname="col6">0.010</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">0.33</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">0.64</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">0.007</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Moderate code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">n.a.</oasis:entry>
         <oasis:entry colname="col5">n.a.</oasis:entry>
         <oasis:entry colname="col6">n.a.</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">n.a.</oasis:entry>
         <oasis:entry colname="col5">n.a.</oasis:entry>
         <oasis:entry colname="col6">n.a.</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">High-rise</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">n.a.</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">n.a.</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">n.a.</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">High code</oasis:entry>
         <oasis:entry colname="col3">Low-rise</oasis:entry>
         <oasis:entry colname="col4">n.a.</oasis:entry>
         <oasis:entry colname="col5">n.a.</oasis:entry>
         <oasis:entry colname="col6">n.a.</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mid-rise</oasis:entry>
         <oasis:entry colname="col4">n.a.</oasis:entry>
         <oasis:entry colname="col5">n.a.</oasis:entry>
         <oasis:entry colname="col6">n.a.</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">High-rise</oasis:entry>
         <oasis:entry colname="col4">n.a.</oasis:entry>
         <oasis:entry colname="col5">n.a.</oasis:entry>
         <oasis:entry colname="col6">n.a.</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e403">n.a.: not assigned.</p></table-wrap-foot></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e1235"><bold>(a)</bold> Example baseline score for a given archetype building typology. <bold>(b)</bold> HAZUS fragility curve database related to the extensive damage limit
state for RC buildings.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f02.png"/>

        </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e1252">Description of the HAZUS MH4 categories involved in the INSPIRE
index (modified after Kircher et al., 2006).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="justify" colwidth="85.358268pt"/>
     <oasis:colspec colnum="2" colname="col2" align="justify" colwidth="398.338583pt"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Description</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">C1: concrete moment <?xmltex \hack{\hfill\break}?>frame</oasis:entry>
         <oasis:entry colname="col2">These buildings have a frame of reinforced concrete columns and beams. Some older concrete frames may be proportioned and detailed such that brittle failure of the frame members can occur in earthquakes, leading to partial or full collapse of the buildings. Modern frames in zones of high seismicity are proportioned and detailed for ductile behaviour and are likely to undergo large deformations during an earthquake without brittle failure of frame members and collapse.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">C2: concrete shear  <?xmltex \hack{\hfill\break}?>wall</oasis:entry>
         <oasis:entry colname="col2">The vertical components of the lateral-force-resisting system in these buildings are concrete shear walls that are usually bearing walls. In older buildings, the walls often are quite extensive and the wall stresses are low but reinforcing is light. In newer buildings, the shear walls often are limited in extent, generating concerns about boundary members and overturning forces.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">C3: concrete infilled  <?xmltex \hack{\hfill\break}?>frame</oasis:entry>
         <oasis:entry colname="col2">These buildings are made of reinforced concrete columns and beams and unreinforced masonry infill walls. In these buildings, the shear strength of the columns, after cracking of the infill, may limit the semi-ductile behaviour of the system.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Building height for C1,  <?xmltex \hack{\hfill\break}?>C2, C3</oasis:entry>
         <oasis:entry colname="col2">Low-rise: 1–3 storeys  <?xmltex \hack{\hfill\break}?>Mid-rise: 4–7 storeys <?xmltex \hack{\hfill\break}?>High-rise:   <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:mo>+</mml:mo></mml:mrow></mml:math></inline-formula> storeys</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Damage state 3 (DS3):  <?xmltex \hack{\hfill\break}?>extensive damage (C1)</oasis:entry>
         <oasis:entry colname="col2">Some of the frame elements have reached their ultimate capacity indicated in ductile frames by large flexural cracks, spalled concrete and buckled main reinforcement; non-ductile frame elements may have suffered shear failures or bond failures at reinforcement splices, or broken ties or buckled main reinforcement in columns which may result in partial collapse.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Damage state 3 (DS3):  <?xmltex \hack{\hfill\break}?>extensive damage (C2)</oasis:entry>
         <oasis:entry colname="col2">Most concrete shear walls have exceeded their yield capacities; some walls have exceeded their ultimate capacities indicated by large, through-the-wall diagonal cracks, extensive spalling around the cracks, and visibly buckled wall reinforcement or rotation of narrow walls with inadequate foundations. Partial collapse may occur due to failure of non-ductile columns not designed to resist lateral loads.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Damage state 3 (DS3):  <?xmltex \hack{\hfill\break}?>extensive damage (C3)</oasis:entry>
         <oasis:entry colname="col2">Most infill walls exhibit large cracks; some bricks may dislodge and fall; some infill walls may bulge out of plane; few walls may fall partially or fully; few concrete columns or beams may fail in shear resulting in a partial collapse. Structure may exhibit permanent lateral deformation.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Pre-code</oasis:entry>
         <oasis:entry colname="col2">Gravity-dominated structures. No seismic design/detailing is available. Such structures are likely built prior to the introduction of seismic codes.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Low code</oasis:entry>
         <oasis:entry colname="col2">According to the provisions in UBC1994 (seismic zone 1), such buildings can sustain a base shear at most equal to 7.5 % of the total weight (assuming an elastic design, no importance factor and stiff soil). The real lateral capacity is likely to be lower than this maximum value.</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Moderate code</oasis:entry>
         <oasis:entry colname="col2">According to the provisions in UBC1994 (seismic zone 2b), such buildings can sustain a base shear at most equal to 20 % of the total weight (assuming an elastic design, no importance factor and stiff soil). The real lateral capacity is likely to be lower than this maximum value.</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">High code</oasis:entry>
         <oasis:entry colname="col2">According to the provisions in UBC1994 (seismic zone 4), such buildings can sustain a base shear at most equal to 40 % of the total weight (assuming an elastic design, no importance factor and stiff soil). The real lateral capacity is likely to be lower than this maximum value.</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1406">To define the baseline score of the INSPIRE index, for each considered
archetype building category, and its corresponding fragility curve, the
probability to exceed DS3 (extensive damage) is calculated
(Fig. 2a) for three levels of PGA, 0.1, 0.25 and
0.4 g, respectively corresponding to low, moderate and high seismicity
levels. The analyst will select the seismicity level appropriate for the
considered building portfolio/geographic area. It is worth noting that, in
modern seismic codes, DS3 is related to the life safety performance
objective. The process above is repeated for each archetype building
category in the HAZUS database, such that it is possible to map the building
basic parameters to the exceeding probability of DS3, conditional to the
considered PGA value (<inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">HAZUS</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mi>P</mml:mi><mml:mfenced open="(" close=")"><mml:mrow><mml:mi mathvariant="normal">DS</mml:mi><mml:mo>≥</mml:mo><mml:mi mathvariant="normal">DS</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">|</mml:mi><mml:mi mathvariant="normal">Mat</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">BSS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">Code</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">Height</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">PGA</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>). The baseline score of the risk
index is set to be proportional to such an exceeding probability, after a
rescaling in the range [1 %, 50 %] based on the minimum and maximum DS3
exceeding probability in the complete (non-filtered) HAZUS database and
calculated according to Eq. (3). In such an equation,
<inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">HAZUS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">max</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">HAZUS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are the maximum and
minimum DS3 exceeding probability in the HAZUS database for the chosen
levels of PGA (indicated with dots in Fig. 2b),
while <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">HAZUS</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the DS3 exceeding probability of the considered
building, for the chosen level of PGA.
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M16" display="block"><mml:mtable rowspacing="0.2ex" class="aligned" columnspacing="1em" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">BL</mml:mi></mml:msub></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mo>=</mml:mo><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">HAZUS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">max</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">HAZUS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mstyle class="stylechange" displaystyle="true"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mo>(</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">HAZUS</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">HAZUS</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Performance modifier</title>
      <p id="d1e1589">Eight secondary parameters are used to define the performance modifier. These parameters are not explicitly considered in the HAZUS framework (and
therefore in the baseline score) but, if present, can
jeopardise the seismic performance of a given building. Firstly, based on
Table 3, a score is assigned for each secondary
parameter (<inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">SCORE</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> in the range [0 %, 100 %]). Therefore, the
performance modifier (<inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">PM</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) is defined as a weighted sum of
each of these scores (Eq. 4, where <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:msub><mml:mi>w</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the
weight of parameter <inline-formula><mml:math id="M20" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>), finally scaling the result in the range [0 %,
50 %]. According to this definition, the
performance modifier can only increase the baseline score, therefore
denoting an increase in seismic fragility. For a more simplified
utilisation, it is also possible to calculate the INSPIRE index considering
the baseline score only. In such a case, a default performance modifier equal
to 25 % is assigned (average of 0 % and 50 %). It is worth mentioning,
however, that any uniform value of the performance modifier will not have
effects on the overall prioritisation, since it will shift all the
calculated indices by the same amount.

                <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M21" display="block"><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">PM</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac></mml:mstyle><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mn mathvariant="normal">8</mml:mn></mml:munderover><mml:msub><mml:mi>w</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:msub><mml:mi mathvariant="normal">SCORE</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></disp-formula></p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e1680">Secondary parameters: definition, available alternatives, related
scores and weights.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="justify" colwidth="99.584646pt"/>
     <oasis:colspec colnum="2" colname="col2" align="justify" colwidth="28.452756pt"/>
     <oasis:colspec colnum="3" colname="col3" align="justify" colwidth="156.490157pt"/>
     <oasis:colspec colnum="4" colname="col4" align="justify" colwidth="28.452756pt"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Secondary parameter</oasis:entry>
         <oasis:entry colname="col2">Scores</oasis:entry>
         <oasis:entry colname="col3">Alternatives</oasis:entry>
         <oasis:entry colname="col4">Weight</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Preservation condition <?xmltex \hack{\hfill\break}?>and/or existing damage <?xmltex \hack{\hfill\break}?></oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>50 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">Significantly affecting performance <?xmltex \hack{\hfill\break}?>Moderately affecting performance <?xmltex \hack{\hfill\break}?>Not affecting performance</oasis:entry>
         <oasis:entry colname="col4">0.0939</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Plan shape</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>50 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">L-shape or irregular <?xmltex \hack{\hfill\break}?>C-shape <?xmltex \hack{\hfill\break}?>Rectangular or regular</oasis:entry>
         <oasis:entry colname="col4">0.0826</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Storey height uniformity</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>50 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">Significantly non-uniform (more than 0.5 m difference) <?xmltex \hack{\hfill\break}?>Moderately non-uniform  (difference <?xmltex \hack{\hfill\break}?>between 0 and 0.5 m) <?xmltex \hack{\hfill\break}?>Uniform</oasis:entry>
         <oasis:entry colname="col4">0.0470</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Added storeys</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">Yes <?xmltex \hack{\hfill\break}?>No</oasis:entry>
         <oasis:entry colname="col4">0.0470</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Infills at ground storey</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">No <?xmltex \hack{\hfill\break}?>Yes</oasis:entry>
         <oasis:entry colname="col4">0.3039</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Short column</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">Yes <?xmltex \hack{\hfill\break}?>No</oasis:entry>
         <oasis:entry colname="col4">0.1817</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Pounding</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>50 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">Pronounced (less than 0.1 m gap) <?xmltex \hack{\hfill\break}?>Moderate (gap between 0.1 and 0.2 m) <?xmltex \hack{\hfill\break}?>None (more than 0.2 m gap)</oasis:entry>
         <oasis:entry colname="col4">0.1817</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unfavourable soil</oasis:entry>
         <oasis:entry colname="col2">100 <?xmltex \hack{\hfill\break}?>0</oasis:entry>
         <oasis:entry colname="col3">Yes (very soft soil; liquefaction is not <?xmltex \hack{\hfill\break}?>explicitly considered) <?xmltex \hack{\hfill\break}?>No</oasis:entry>
         <oasis:entry colname="col4">0.0621</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1894">The secondary parameters defining the performance modifiers are deemed to
complement the information in the HAZUS fragility curves. The idea is that
the baseline score (HAZUS fragility database) provides the (conditional)
seismic risk of a given building class, while the secondary parameters are
related to building-specific vulnerability factors. The secondary parameters
have been selected based on the fundamental rules of seismic design (e.g.
Paulay and Priestley, 1992) and the commonly observed post-earthquake damage
on RC structures (e.g. Elnashai and Di Sarno, 2008; Palermo et al., 2017;
De Luca et al., 2018). For each of them, Table 3
provides guidance on the selection of the alternatives. The score for each
alternative has been defined based on a uniform partitioning of the range
[0 %, 100 %].</p>
      <p id="d1e1898">Evidently, the secondary parameters defining the performance modifier do not
have the same influence on the overall vulnerability and risk. For example,
the absence of infill<?pagebreak page1370?> walls at the ground storey can lead to a soft-storey
mechanism, which in turn can results in local or global collapse. On the
other hand, the addition of storeys to a building can somehow increase its vulnerability, but it is generally less likely this would lead to collapse. Therefore, the weight of the former parameter should be higher than the latter, to reflect
such a different effect on the overall seismic risk.</p>
      <p id="d1e1901">To this extent, the AHP, originally proposed by
Saaty (1980), is used to calibrate the weights in the proposed procedure.
This allows one to have a rational and mathematically consistent assignment of
the weights, which is based on pairwise comparisons between the secondary
parameters and uses eigenvalues theory. Hence, the selected weights can reflect
the relative importance of each parameter with respect to the others in the
determination of the performance<?pagebreak page1371?> modifier. It is worth mentioning that such
an approach has been successfully adopted in other earthquake engineering
applications, such as the selection of the optimal seismic retrofitting
strategy for case-study buildings (Caterino et al., 2008). Also, it is worth
mentioning that, in its current version, the expert judgement defining the
weights adopted in the procedure is provided by the authors. However, such
weights can be further updated considering the opinion of a group of experts
in the field of structural and earthquake engineering.</p>
      <p id="d1e1904">After the definition of the parameters involved in the analysis, the first
step of the process consists of expressing an expert opinion about every
possible pairwise comparison of those parameters. Given two parameters
<inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, the relative importance of <inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> over <inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is
expressed with the coefficients <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, defined according to
Table 4. For the calibration proposed in this
paper, the pairwise comparisons are performed considering the relative
influence of the secondary parameters on the life safety performance
objective. The related judgement matrix [<bold>A</bold>] containing the 27 pairwise comparisons is given in Table 5. As an
example, the presence of infill walls at the ground storey has been
considered to be significantly more important than the presence of unfavourable soil,
given its implications on life safety. Therefore, the related <inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>
parameter is set to 9.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e1986">Scale of relative importance of the secondary parameters (Saaty,
1980).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Relative importance</oasis:entry>
         <oasis:entry colname="col2">Description</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(<inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">Parameters <inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are equally important</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2">Parameter <inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is moderately more important than <inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5</oasis:entry>
         <oasis:entry colname="col2">Parameter <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is essentially more important than <inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">7</oasis:entry>
         <oasis:entry colname="col2">Parameter <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is demonstrably more important than <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">9</oasis:entry>
         <oasis:entry colname="col2">Parameter <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is significantly more important than <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2, 4, 6, 8</oasis:entry>
         <oasis:entry colname="col2">Intermediate values between the two adjacent judgements</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Reciprocal of</oasis:entry>
         <oasis:entry colname="col2">If criterion <inline-formula><mml:math id="M39" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> compared to <inline-formula><mml:math id="M40" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula> gives one of the above, then <inline-formula><mml:math id="M41" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula>,</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">the above</oasis:entry>
         <oasis:entry colname="col2">when compared to <inline-formula><mml:math id="M42" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, gives its reciprocal</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e2242">Once the pairwise comparisons have been performed, the vector <inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:mo mathvariant="italic">{</mml:mo><mml:mi mathvariant="bold-italic">w</mml:mi><mml:mo mathvariant="italic">}</mml:mo></mml:mrow></mml:math></inline-formula> containing the weights of the secondary parameters
is found by solving the eigenvalue problem <inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mi mathvariant="bold">A</mml:mi><mml:mi mathvariant="bold-italic">w</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mi mathvariant="normal">max</mml:mi></mml:msub><mml:mi mathvariant="bold-italic">w</mml:mi></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mi mathvariant="normal">max</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the largest eigenvalue. The
principal right eigenvector of the [<bold>A</bold>] matrix is the vector of the
weights <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mo mathvariant="italic">{</mml:mo><mml:mi mathvariant="bold-italic">w</mml:mi><mml:mo mathvariant="italic">}</mml:mo></mml:mrow></mml:math></inline-formula>, after normalisation with
respect to its sum. Using such an approach allows one to measure the consistency of
the pairwise comparisons, therefore minimising the chance to have a random
prioritisation of the parameters. In fact, if the pairwise comparisons are
performed in a perfectly consistent manner, the [<bold>A</bold>] matrix has only
one eigenvalue equal to its rank, and the coefficients <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are equal to
the ratio <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:msub><mml:mi>w</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>w</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of the weights related to the parameters <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. Practically, the comparisons are unlikely to be perfectly
consistent, and the first eigenvalue of the [<bold>A</bold>] matrix will be
slightly different than its rank, while the other eigenvalues are close to
zero.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5" specific-use="star"><?xmltex \currentcnt{5}?><label>Table 5</label><caption><p id="d1e2367">Judgement matrix adopted for the calibration of the weights.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="9">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:colspec colnum="9" colname="col9" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Preservation</oasis:entry>
         <oasis:entry colname="col3">Plan</oasis:entry>
         <oasis:entry colname="col4">Storey height</oasis:entry>
         <oasis:entry colname="col5">Added</oasis:entry>
         <oasis:entry colname="col6">Infills at</oasis:entry>
         <oasis:entry colname="col7">Short</oasis:entry>
         <oasis:entry colname="col8">Pounding</oasis:entry>
         <oasis:entry colname="col9">Unfavourable</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">condition</oasis:entry>
         <oasis:entry colname="col3">shape</oasis:entry>
         <oasis:entry colname="col4">uniformity</oasis:entry>
         <oasis:entry colname="col5">storeys</oasis:entry>
         <oasis:entry colname="col6">ground storey</oasis:entry>
         <oasis:entry colname="col7">column</oasis:entry>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9">soil</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Preservation condition</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry colname="col3">1</oasis:entry>
         <oasis:entry colname="col4">2</oasis:entry>
         <oasis:entry colname="col5">2</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9">2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Plan shape</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry colname="col3">1</oasis:entry>
         <oasis:entry colname="col4">2</oasis:entry>
         <oasis:entry colname="col5">2</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Storey height uniformity</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">1</oasis:entry>
         <oasis:entry colname="col5">1</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Added storeys</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">1</oasis:entry>
         <oasis:entry colname="col5">1</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Infills at ground storey</oasis:entry>
         <oasis:entry colname="col2">3</oasis:entry>
         <oasis:entry colname="col3">3</oasis:entry>
         <oasis:entry colname="col4">6</oasis:entry>
         <oasis:entry colname="col5">6</oasis:entry>
         <oasis:entry colname="col6">1</oasis:entry>
         <oasis:entry colname="col7">2</oasis:entry>
         <oasis:entry colname="col8">2</oasis:entry>
         <oasis:entry colname="col9">6</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Short column</oasis:entry>
         <oasis:entry colname="col2">2</oasis:entry>
         <oasis:entry colname="col3">2</oasis:entry>
         <oasis:entry colname="col4">4</oasis:entry>
         <oasis:entry colname="col5">4</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">1</oasis:entry>
         <oasis:entry colname="col8">1</oasis:entry>
         <oasis:entry colname="col9">4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Pounding</oasis:entry>
         <oasis:entry colname="col2">2</oasis:entry>
         <oasis:entry colname="col3">2</oasis:entry>
         <oasis:entry colname="col4">4</oasis:entry>
         <oasis:entry colname="col5">4</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">1</oasis:entry>
         <oasis:entry colname="col8">1</oasis:entry>
         <oasis:entry colname="col9">4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Unfavourable soil</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">2</oasis:entry>
         <oasis:entry colname="col4">1</oasis:entry>
         <oasis:entry colname="col5">1</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9">1</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e2939">Therefore, the consistency of the pairwise comparison is measured by
calculating the consistency index (CI) using Eq. (5),
where <inline-formula><mml:math id="M74" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> is the rank of the matrix. The CI is compared to the random
consistency index (RCI), which is the average consistency index of a large
number of randomly generated reciprocal matrices using the scale (<inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:math></inline-formula>, …, 1, …, 9). According to Saaty (1980), for <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:mo>×</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula>
matrices the random consistency index is equal to 1.41. According to the
same study, if the CI is smaller than 10 % of the RCI (Eq. 6), the final choice of the weights is logically
sound and not a result of random prioritisation. In general, if such
a criterion is not satisfied for the performed pairwise comparisons, the whole
process should be repeated until an acceptable consistency is achieved. For the
pairwise comparisons in this paper, the consistency index is equal to
2.1 %, which is considered acceptable.</p>
      <p id="d1e2973"><disp-formula specific-use="gather" content-type="numbered"><mml:math id="M77" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E5"><mml:mtd><mml:mtext>5</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mi mathvariant="normal">CI</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mi mathvariant="normal">max</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mi>n</mml:mi></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E6"><mml:mtd><mml:mtext>6</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="normal">CI</mml:mi><mml:mi mathvariant="normal">RCI</mml:mi></mml:mfrac></mml:mstyle><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Multi-hazard considerations</title>
      <p id="d1e3034">In many common situations, it is very likely that seismic considerations
alone are not enough to define a robust prioritisation scheme for the
decision-making process by a governmental agency or the owner of a large
building portfolio. To deal with such a scenario, this paper presents a simple
methodology to include other hazards in the prioritisation scheme.</p>
      <p id="d1e3037">Simplified analytical indices are available for the estimation of the
vulnerability of buildings to natural hazards different than seismic hazard,
such as tsunami (e.g. Dall'Osso et al., 2016), flood (e.g. Stephenson and
D'Ayala, 2014; Pazzi et al., 2016; Nassipour et al., 2018) and wind (e.g.
Womble<?pagebreak page1372?> et al., 2016). Once the desired single-hazard vulnerability
indices (<inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi>k</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) are computed, a combined, multi-hazard index can be
defined as the multi-dimensional distance from the origin of the system of
reference (Eq. 7). Although this concept is
applicable regardless of the number of considered hazards, a two-dimensional
example is presented in Fig. 3. Supposing that
both hazard 1 and 2 are defined over a range [1 %, 100 %], the
combined index will be defined on the range [1 %, 141.4 %]. However,
this can be rescaled in any other desired range without affecting the
prioritisation list of the considered building portfolio. It is worth
mentioning that cumulative damage related to subsequent hazards is outside
the scope of such a simplified multi-hazard index.

                <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M79" display="block"><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">multi</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msub><mml:mo>∑</mml:mo><mml:mi>k</mml:mi></mml:msub><mml:msubsup><mml:mi>I</mml:mi><mml:mi>k</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:msqrt></mml:mrow></mml:math></disp-formula></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e3080">Definition of a two-dimensional (<inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) multi-hazard index.</p></caption>
          <?xmltex \igopts{width=142.26378pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f03.png"/>

        </fig>

</sec>
<?pagebreak page1373?><sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Dealing with subjectivity</title>
      <p id="d1e3110">According to the definition of the seismic risk prioritisation index given
in Sect. 3, it appears evident that a degree of subjectivity is always involved in the calculation.
<list list-type="order"><list-item>
      <p id="d1e3115">The baseline score is based on the fragility functions available in the
HAZUS MH4 guidelines. Although such a model is largely based on numerical
analyses of building models, the results are provided for a limited number
of structural categories. The user should carefully select the category that
best matches with the characteristics of the considered buildings, with
special reference to the code level parameter.</p></list-item><list-item>
      <?pagebreak page1374?><p id="d1e3119">The weights needed for the calculation of the performance modifier are based
on a subjective set of pairwise comparisons between the secondary
parameters, although this is derived in a mathematically consistent and
rational way that allows us to minimise the chance of having randomly assigned
weights.
<?xmltex \hack{\newpage}?></p></list-item><list-item>
      <p id="d1e3124">The ratio between the maximum possible baseline score and the maximum
possible performance modifier is arbitrarily set to unity, i.e.
<inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:mi mathvariant="normal">BL</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">max</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">50</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:mi mathvariant="normal">PM</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">max</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">50</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula>.</p></list-item></list>
It is worth noting that the subjectivity is an intrinsic component of any
simplified vulnerability index, including the INSPIRE index. Therefore,
rather than assessing a single building, these methods should only be used
to derive a proxy for the relative vulnerability (or risk) of buildings in a
given portfolio and to define a prioritisation scheme for possible risk-mitigation actions. However, in this section some measures are proposed to
control and minimise the subjectivity involved with the definition of the
index. An example of such measures is given in Sect. 4, in relation to a real building portfolio application.</p>
      <p id="d1e3176">It is virtually impossible to perfectly match the considered buildings with
the archetype buildings in HAZUS. However, a careful examination of the
characteristics of the considered buildings should be carried out to better
select the appropriate HAZUS categories. Characteristics such as the
presence of strong beams vs. weak columns should be considered, which can
lead to a pre-code classification or documented structural retrofit
measures, which can lead to higher code level classification. A review
of the (history of the) structural and/or seismic codes appropriate for the
considered buildings can considerably reduce the level of subjectivity.
These can be compared to the different provisions in UBC1994, defining
equivalence relationships. Any information related to the year of
construction (or design) of the considered buildings is fundamental in such
a process. Overall, it is deemed that the assignment of the HAZUS categories
to the considered buildings should reflect their expected differences in
their seismic performance rather than perfectly match the properties of the
archetype in the HAZUS category definition.</p>
      <?pagebreak page1375?><p id="d1e3179"><?xmltex \hack{\newpage}?>As an alternative to the HAZUS definition, the baseline score can be
redefined adopting, if available, a portfolio-specific set of fragility
curves. To this aim, the OpenQuake platform (open-source, <uri>https://storage.globalquakemodel.org/openquake</uri>, last access: 30 May 2019), by the Global Earthquake Model (GEM) Foundation, might be used. Among other capabilities, such
a platform contains large databases of empirical and numerical
fragility and vulnerability models appropriate for many structural typologies
and many regions of the world.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e3189">Map of the school buildings in Banda Aceh, including non-surveyed
ones. Background map by © OpenStreetMap contributors 2019. Distributed under a Creative Commons BY-SA License.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f04.png"/>

        </fig>

      <p id="d1e3198">An illustrative set of weights needed to calculate the performance modifier
is given in this paper. However, a case-specific AHP, for instance involving
groups of local experts, can be performed to derive new weights that match
the characteristics of the considered building portfolio. Such a procedure
cannot remove the subjectivity related to the performance modifier but
provides the user with a tool to reduce it and have a close match between
the analysed building portfolio and the adopted weights.</p>
      <p id="d1e3201">Finally, the subjectivity related to the ratio between the maximum possible
baseline score and performance modifier can be tested through a sensitivity
analysis. For a given building portfolio, the idea is to repeat the
calculation of the seismic index with different values of the maximum
possible performance modifier. This allows one to check the reliability of the
priority list to this assumption. If slight modifications in the maximum
possible performance modifier lead to high differences in the resulting
priority list, engineering judgement should be adopted to justify the final
choice.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Illustrative application: school building portfolio in Banda Aceh,
Indonesia</title>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Description of the case-study portfolio and definition of an archetype
building</title>
      <p id="d1e3221">The case-study portfolio selected for this study consists of 85 RC buildings
belonging to 44 school compounds located in Banda Aceh, the capital and
largest city in the province of Aceh, Indonesia
(Fig. 4). Banda Aceh is located in the island of
Sumatra and, according to the 2000 census, has a population of 219 070 people (Seta, 2000). The city was severely affected by the 26 December 2004
Indian Ocean earthquake (moment magnitude, <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">9.1</mml:mn></mml:mrow></mml:math></inline-formula>), being the closest
major city to the event location. Due to the effects of the following
devastating tsunami, the city suffered from 167 000 deaths and catastrophic
damage to structures and infrastructures. It is worth noting that Indonesia
suffered a USD 4.5 billion economic loss for this event (Pomonis et al., 2006).
In the Aceh region, 45 000 students and 1870 teachers died and 2065 education facilities were damaged (BAPPENAS, 2006).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e3241">Sample photos of the building portfolio (taken on 16–19 October 2018).</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f05.jpg"/>

        </fig>

      <p id="d1e3250"><?xmltex \hack{\newpage}?>A RVS campaign through the INSPIRE form (Fig. 1)
was carried out to collect administrative, geometric and mechanical data
related to the investigated buildings. The RVS campaign
(Fig. 5) was conducted by three teams composed of
one experienced engineer and two final-year (one undergraduate and one
postgraduate) local engineering students working for 4 d. The surveys
were conducted in all the suburbs of Banda Aceh
(Fig. 6a) to obtain a clear overview of the
construction practice in the city. For all the surveyed buildings, the BSS
is a reinforced concrete frame with infills. The majority (81 %) of the
buildings in the portfolio have a rectangular plan, with the remaining 19 %
composed of L-, C- or T-shaped plans (Fig. 6b).
A total of 68 % of the surveyed buildings are two storeys high, while one- and
three-storey buildings represent 15 % and 16 % of the portfolio,
respectively (Fig. 6c). The year of construction
for each building was retrieved from the school signboard, registry or by
interview of the school principal. Figure 6d shows
that few buildings (18 %) survived the 2004 earthquake–tsunami sequence;
hence, the majority of the portfolio (57 %) was constructed between 2005
and 2011, while the remaining 25 % was built from 2013 onwards.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e3257">Statistics for the 85 surveyed school buildings. <bold>(a)</bold> Surveyed schools per suburb; <bold>(b)</bold> plan shape; <bold>(c)</bold> number of storeys; <bold>(d)</bold> year of construction.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f06.png"/>

        </fig>

      <p id="d1e3278">The accurate knowledge of the year of construction is essential for the
structural characterisation of the portfolio. In fact, such information can
be coupled with the history/evolution of the available structural and/or
seismic codes to derive minimum-by-law dimensions of the structural members,
reinforcement detailing, level of considered vertical and lateral forces in
the design, etc. In this specific case, the appropriate structural code for
the whole portfolio is the SKBI 1.3.53.1987 (Badan Standardasi Nasional, BSN, 1987). The first seismic
code appropriate for the region is the SNI 1726:2002 (BSN, 2002), which is
inspired by the American Uniform Building Code 1997 (or UBC, 1997; ICBO, 1997), which also
facilitates the compatibility with the HAZUS framework. Stricter seismic
provisions were adopted when the seismic code was updated in the SNI 1726:2012 (BSN, 2012), which is fully consistent with the American ASCE 7–10
(ASCE, 2010). Therefore, apart from a minority (12) of buildings constructed
before 2002, approximately half of the buildings are constructed according
to the SNI 1726:2002 (lower) standards while the other half refers to the
updated SNI 1726:2012, with nominally better nominal seismic performance.</p>
      <p id="d1e3281">The analysis above, based only on the information of the INSPIRE forms,
allows one to identify an archetype building which represents the construction
practice for school building in Banda Aceh. The archetype building is a
two-storey, rectangular RC building. Figure 7 shows
the geometrical characteristics of the archetype building geometry, which
are based on the modal (most frequent) values of the empirical distributions
(histograms) considering only the rectangular, two-storey buildings in the
portfolio (69). The archetype building has 10 bays in the longitudinal direction (one
for the staircase, three for each classroom). In the transverse<?pagebreak page1376?> direction
there are two 3.5 bays and a 2 m corridor bay. The storey height is equal to
3.5 m. Columns of <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.4</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> are adopted, except for the corridor columns, whose
dimensions are <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.3</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>. Finally, the dimensions of the typical beams are <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.3</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">0.44</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>. The dimensions of beams and columns are validated with the simulated
design approaches according to the above-mentioned codes.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e3346">Two-storey, rectangular buildings: geometry trends and adopted
values for the archetype building. <bold>(a)</bold> Plan view of the archetype building; <bold>(b–h)</bold> histograms of the geometric parameters.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f07.png"/>

        </fig>

      <p id="d1e3361">Considering the same geometry, two different sets of structural details are
provided, to reflect the SNI 1726:2002 and SNI 1726:2012 seismic codes.
Table 6 provides examples of structural
reinforcement for typical members. It is worth mentioning that, for the
post-2012 archetype structure, the cross-section height of beams and columns
are respectively 5 cm and 10 cm larger than the corresponding members in the
pre-2012 archetype structure. The reinforcement of the structural members is
selected by cross-checking visual information (see
Fig. 5) with the outcome of both gravity-based
and seismic-based simulated design according to the SNI codes. To this aim,
acting loads are calculated considering permanent dead loads (according to
the suggested material properties in SKBI 1.3.53.1987) and live load equal to 5 kPa
(1 kPa for the roof). Gravity axial load on columns is calculated based on a
tributary area approach. This cross-checking exercise has shown that the
real observed amount of longitudinal reinforcement is greater than the
minimum by code. On the other hand, based on the limited visual information
available for the transverse reinforcement, no joint stirrups are
conservatively considered for both the pre-2012 and post-2012 classes,
regardless of the requirement in both codes.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T6" specific-use="star"><?xmltex \currentcnt{6}?><label>Table 6</label><caption><p id="d1e3368">Typical structural details for the archetype building(s).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Materials (mean values)</oasis:entry>
         <oasis:entry colname="col3">Typical beam</oasis:entry>
         <oasis:entry colname="col4">Typical column</oasis:entry>
         <oasis:entry colname="col5">Typical joint</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Pre-2012</oasis:entry>
         <oasis:entry colname="col2">Concrete <inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">21.5</mml:mn></mml:mrow></mml:math></inline-formula> MPa</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> top</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> top</oasis:entry>
         <oasis:entry colname="col5">No stirrups</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Long. steel <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">y</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">400</mml:mn></mml:mrow></mml:math></inline-formula> MPa</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> bottom</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> bottom</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Tran. steel <inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">y</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">240</mml:mn></mml:mrow></mml:math></inline-formula> MPa</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">10</mml:mn><mml:mi mathvariant="normal">@</mml:mi><mml:mn mathvariant="normal">150</mml:mn></mml:mrow></mml:math></inline-formula> mm stirrups</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">10</mml:mn><mml:mi mathvariant="normal">@</mml:mi><mml:mn mathvariant="normal">200</mml:mn></mml:mrow></mml:math></inline-formula> mm stirrups</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Post-2012</oasis:entry>
         <oasis:entry colname="col2">Concrete <inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">24</mml:mn></mml:mrow></mml:math></inline-formula> MPa</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> top</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> top</oasis:entry>
         <oasis:entry colname="col5">No stirrups</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Long. steel <inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">y</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">400</mml:mn></mml:mrow></mml:math></inline-formula> MPa</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> bottom</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> bottom</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Tran. steel <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">y</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">240</mml:mn></mml:mrow></mml:math></inline-formula> MPa</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">10</mml:mn><mml:mi mathvariant="normal">@</mml:mi><mml:mn mathvariant="normal">150</mml:mn></mml:mrow></mml:math></inline-formula> mm stirrups</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mi mathvariant="normal">Φ</mml:mi><mml:mn mathvariant="normal">10</mml:mn><mml:mi mathvariant="normal">@</mml:mi><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula> mm stirrups</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e3371">Note: <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the concrete compressive cylinder strength; <inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">y</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the
steel yield stress.</p></table-wrap-foot></table-wrap>

</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Prioritisation scheme</title>
      <p id="d1e3774">Based on the data collected with the forms, the INSPIRE seismic risk
prioritisation index is calculated for the whole portfolio. Moreover, the
tsunami PTVA4 index (Dall'Osso et al., 2016) is calculated, finally
combining these results to derive a multi-hazard index. It is worth
mentioning that the resulting index values are arbitrarily categorised in
three groups, respectively green, yellow and red tags by defining two
threshold values for the various indices. The definition of such thresholds
is essentially a subjective (often<?pagebreak page1377?> political) choice that shapes the
prioritisation scheme, based for instance on resources availability. For a
governmental agency, those can be calibrated estimating the average
structural retrofit (or relocation) cost per building and defining the
amount of available public funding in two or more time windows (e.g. 1 and
5 years) to obtain specified risk-reduction objectives. As a proof of
concept, in this paper the thresholds are selected to be equal to 33 % and
66 % for the calculated seismic, tsunami or multi-hazard indices.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><label>Figure 8</label><caption><p id="d1e3779">Application to the seismic and tsunami indices to 85 RC school
buildings in Banda Aceh, Indonesia. <bold>(a, c, e)</bold> Seismic, tsunami and multi-hazard indices; <bold>(b, d, f)</bold> map representation of the same indices. Background maps by © OpenStreetMap contributors 2019. Distributed under a Creative Commons BY-SA License.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f08.png"/>

        </fig>

      <p id="d1e3794">The PTVA index, similarly to the proposed INSPIRE index, allows one to derive
the relative tsunami vulnerability of a building. It is calculated as a
weighted sum of two parameters: the structural vulnerability and the
so-called water vulnerability. The first parameter depends on three
factors: the type of the lateral resisting system, the depth of the flood
water at the building location and the degree of external protection (e.g.
presence of seawalls). The water vulnerability depends on the ratio of
the inundated-to-total number of storeys. This parameter is calculated using the inundation data from the 2004 Indian Ocean
tsunami. In particular, Iemura et al. (2012) provide 85 field-measurements of
the tsunami height (from the ground) for the city of Banda Aceh. For the
purpose of this paper, a linear regression (<inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.66</mml:mn></mml:mrow></mml:math></inline-formula>) is performed to
define a linear relationship between distance from the coast and tsunami
height. The calculation of the final risk-related index is dependent on
scoring parameters assigned according the number of storeys of the building,
its material, the percentage of openings (e.g. windows), foundation type,
impacting objects, orientation and shape of the building, and its position
with respect to a building row.<?pagebreak page1378?> Although the
name refers to vulnerability, the PTVA index somehow refers to tsunami risk,
since the expected hazard is also considered. This facilitates the
compatibility with the INSPIRE index.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><?xmltex \currentcnt{9}?><label>Figure 9</label><caption><p id="d1e3815">Sensitivity analysis for the baseline-to-performance modifier
ratio. Maximum performance modifier equal to <bold>(a)</bold> 20 %, <bold>(b)</bold> 30 %, <bold>(c)</bold> 40 %, and <bold>(d)</bold> 50 %.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f09.png"/>

        </fig>

      <p id="d1e3836">Figure 8a and b show the application of the INSPIRE
seismic risk prioritisation index to the considered portfolio. To calculate
the baseline scores, the HAZUS fragility curves related to the C1 category
“concrete moment frame” are used. Since the infills of the investigated
frames are made of a single layer of poor-quality clay bricks, their
presence is neglected. According to the analysis of the year of construction
and the history of the structural and seismic codes in Indonesia, the categories
pre-code and low-code are adopted for the pre-2012 and post-2012 buildings,
respectively. Given the particularly small differences in the
characteristics of the considered buildings, the INSPIRE index is particularly similar
for the whole portfolio [32 %, 64 %]. The slight differences in the
value of the index are due to the performance modifiers, mainly governed by
short columns and/or pounding for the majority of the schools. This is a
further confirmation of the uniformity of the construction practice for
school buildings in Banda Aceh, also observed in other countries (e.g.
Nassirpour et al., 2018; Zhou et al., 2018). It is worth mentioning that,
for this particular portfolio, soil condition is not influencing the
performance modifier, since the unfavourable soil parameter is set to
“yes” for all the buildings. On the other hand, the results for the PTVA
tsunami index (Fig. 8c, d) show a larger
variability [7 %, 75 %] and a clear correlation between the distance
from the coast and the relative tsunami risk. This result, although
preliminary, might suggest that the distance from the coast can be used as a
very simple proxy for the water vulnerability parameter in the tsunami
PTVA index.</p>
      <p id="d1e3839">Given the above-mentioned trends, the combination of the seismic and tsunami
indices (Fig. 8e, f) clearly indicates that the
tsunami hazards play a substantial role in determining<?pagebreak page1379?> the prioritisation
scheme for the school buildings in the city of Banda Aceh. Indeed, the
overall trend of the multi-hazard results is practically equal to the trend
of the tsunami index results. For instance, the developed maps could be used
to identify safer areas where strategic buildings (e.g. schools or
hospitals) should be located, increasing the awareness of vulnerabilities
that could be integrated in emergency planning for critical infrastructure
disruption (e.g. Pescaroli and Alexander, 2016).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T7" specific-use="star"><?xmltex \currentcnt{7}?><label>Table 7</label><caption><p id="d1e3845">Numerical modelling strategy.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="justify" colwidth="113.811024pt"/>
     <oasis:colspec colnum="3" colname="col3" align="justify" colwidth="113.811024pt"/>
     <oasis:colspec colnum="4" colname="col4" align="justify" colwidth="85.358268pt"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Modelling approach</oasis:entry>
         <oasis:entry colname="col3">Mechanical characterisation model</oasis:entry>
         <oasis:entry colname="col4">Notes</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Beams</oasis:entry>
         <oasis:entry colname="col2">Mono-dimensional Giberson elements (Sharpe, 1976) with moment–curvature characterisation of end sections</oasis:entry>
         <oasis:entry colname="col3">Moment–curvature analysis and 50 % increase in negative moment capacity due to flange effect (NZSEE, 2017)</oasis:entry>
         <oasis:entry colname="col4">Software CUMBIA (Montejo and Kowalsky, 2007; Gentile, 2017) for moment–curvature</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Columns</oasis:entry>
         <oasis:entry colname="col2">Mono-dimensional Giberson elements (Sharpe, 1976) with moment–axial load characterisation of end sections</oasis:entry>
         <oasis:entry colname="col3">Moment–axial load interaction diagram analysis</oasis:entry>
         <oasis:entry colname="col4">Software CUMBIA for moment–axial load</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Joints</oasis:entry>
         <oasis:entry colname="col2">Rigid ends in the beam–column intersections which are connected with non-linear moment-rotation springs</oasis:entry>
         <oasis:entry colname="col3">Behaviour of the springs follows the equivalent column moment vs. drift curve (NZSEE, 2017)</oasis:entry>
         <oasis:entry colname="col4">Drift limits for joint panels based on experimental tests (NZSEE, 2017)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e3927">To control the role of the subjectivity in calculating the INSPIRE seismic
index, a sensitivity study is conducted. The seismic index is applied to the
entire portfolio four times (Fig. 9), by
considering that the maximum value of the performance modifier is equal to
20 %, 30 %, 40 % and 50 %. The maximum value of the baseline score
is respectively equal to 80 %, 70 %, 60 % and 50 %.</p>
      <p id="d1e3931">The results of the seismic index are ranked in descending order of risk. The
results clearly show that, for this portfolio, the overall priority list is
rather insensitive to the maximum baseline-to-performance modifier ratio.
Indeed, a small number of swaps in the priority list is sought and, with
the same definition of the thresholds for the tags, the number of buildings
in each category has a negligible dependency on the ratio above.</p>
</sec>
<sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Analytical and numerical seismic fragility analyses for the archetype
building(s)</title>
      <p id="d1e3942">As discussed above, the INSPIRE form provides enough data to build refined
numerical models for one or more selected<?pagebreak page1380?> buildings, in a multi-level
approach. While the previous sections illustrate the portfolio-level
approach (relative-risk prioritisation), this section illustrates a possible
structure-specific application of the proposed framework. To this aim, the
archetype building(s) defined in Sect. 4.1 is (are) further analysed by means of non-linear static and non-linear dynamic analyses to derive structure-specific fragility curves. Those are derived considering a two-dimensional representation of the longitudinal and transverse frames that compose the archetype building. As discussed above, due to their small thickness and poor quality, infills are not considered in the models. Both the pre-2012 and the post-2012 archetype buildings are analysed, leading to four different computational models.</p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F10" specific-use="star"><?xmltex \currentcnt{10}?><label>Figure 10</label><caption><p id="d1e3947">Numerical modelling strategy (from Gentile et al., 2019a, Taylor &amp; Francis, all rights reserved).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f10.png"/>

        </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F11" specific-use="star"><?xmltex \currentcnt{11}?><label>Figure 11</label><caption><p id="d1e3958">Non-linear static analyses results for the archetype building. <bold>(a–d)</bold> Plastic mechanisms at DS3; <bold>(e–f)</bold> capacity curves.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f11.png"/>

        </fig>

      <?pagebreak page1382?><p id="d1e3974"><?xmltex \hack{\newpage}?>The simple lateral mechanism analysis (SLaMA) method is firstly used to obtain a
first estimation of the non-linear force-displacement curve of the building.
SLaMA (NZSEE, 2017; Gentile et al., 2019a, b, c, d) is a tool to derive both the
expected plastic mechanism and the capacity curve of RC frame, wall and
dual-system buildings by using a “by-hand” procedure (i.e. using an
electronic spreadsheet). This allows one to identify potential structural
weaknesses in the lateral resisting mechanism and to test the
reliability of numerical computer models in capturing the most probable
behaviour of a structure. It is worth mentioning that each beam and column
in the system is characterised considering many possible failure mechanisms
(i.e. flexure, bar buckling, lap-splice failure, shear), considering that
the weakest link will govern the overall structural behaviour.</p>
      <p id="d1e3978">The results of SLaMA are compared to refined numerical pushover analyses
carried out with the finite-element modelling software Ruaumoko (Carr, 2016). The adopted
modelling strategy, previously validated on experimental results (Magenes
and Pampanin, 2004), is based on a lumped plasticity approach and is summarised in Table 7 and Fig. 10.
The characterisation of the structural members is consistent with the approach
adopted for SLaMA. P-delta effects are not
modelled, given that the building is just two storeys high and made of RC.
Fully fixed boundary conditions are considered at the base, and floor
diaphragms are modelled as rigid in plane. A uniform force profile is
adopted.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12" specific-use="star"><?xmltex \currentcnt{12}?><label>Figure 12</label><caption><p id="d1e3983">Archetype building: fragility curves based on cloud analysis,
calculated for <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (0.5 s). <bold>(a, c)</bold> Pre-2012 building; <bold>(b, d)</bold> post-2012 building.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://nhess.copernicus.org/articles/19/1365/2019/nhess-19-1365-2019-f12.png"/>

        </fig>

      <p id="d1e4009">Figure 11 shows the results of the non-linear
static analyses. Firstly, the fundamental periods of such frames in the
transverse and longitudinal directions are equal to 0.55 and 0.47 s for the
pre-2012 archetype and to 0.5 and 0.44 s for the post-2012 one. The plastic
mechanism (numerically based) of the pre-2012 archetype frames is very
similar to the one related to the post-2012 ones, in both the transverse and
longitudinal directions. In the transverse direction, the plastic mechanism,
calculated at the onset of the extensive damage state (DS3), is characterised
by the development of plastic hinges for the roof beams and base columns,
as well as joint shear hinges at the first storey (mixed-sway mechanism). No
brittle shear failure is registered for beams and columns (both considering
SLaMA and the pushover analysis). The beam causing DS2 (yielding) is
highlighted in a blue circle in Fig. 11a, while
the joint panel causing DS3 is highlighted with a red circle. In the
longitudinal direction, the DS3 plastic mechanism is characterised by a
soft storey at the first storey, with one internal column causing DS2, but
the DS3 displacement of the structure is limited by the ultimate drift in
the beam–column joint, highlighted with a red circle in
Fig. 11b and d. According to the similarities in the
plastic mechanism, the capacity curves for the pre-2012 and post-2012
archetype frames are particularly consistent. It is worth mentioning that
the DS3 base shear for the post-2012 archetype building is 16 % and 19 %
greater than the pre-2012 archetype, respectively in the transverse and
longitudinal directions.</p>
      <p id="d1e4012">On the other hand, negligible differences are recorded for the displacement
at DS3, for both the pre- and post-2012 archetypes and both transverse and
longitudinal directions. This is because, in all four cases, the failure of
one joint panel causes the attainment of such a damage state. The displacement
in the force-displacement curves is calculated at the effective height
(Priestley et al., 2007), which is approximately equal to 5.50 m. It is
evident that the structure has a particularly low displacement capacity,
since this is limited by the low drift capacity of the joint panels.
Finally, there is a satisfactory agreement between SLaMA and the
numerically based pushover, especially considering that the ultimate
displacement in the SLaMA curves represents DS3.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T8" specific-use="star"><?xmltex \currentcnt{8}?><label>Table 8</label><caption><p id="d1e4019">Fragility curves of the archetype frames based on cloud analysis
(<inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula> s).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right" colsep="1"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry rowsep="1" namest="col3" nameend="col4" align="center" colsep="1">Pre-2012 </oasis:entry>
         <oasis:entry rowsep="1" namest="col5" nameend="col6" align="center">Post-2012 </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M110" display="inline"><mml:mi mathvariant="italic">μ</mml:mi></mml:math></inline-formula>: median <inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>(<inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) (g)</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M113" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>: dispersion</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M114" display="inline"><mml:mi mathvariant="italic">μ</mml:mi></mml:math></inline-formula>: median <inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>(<inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) (g)</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M117" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>: dispersion</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Transverse</oasis:entry>
         <oasis:entry colname="col2">DS1</oasis:entry>
         <oasis:entry colname="col3">0.1823</oasis:entry>
         <oasis:entry colname="col4">0.5066</oasis:entry>
         <oasis:entry colname="col5">0.2078</oasis:entry>
         <oasis:entry colname="col6">0.4226</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DS2</oasis:entry>
         <oasis:entry colname="col3">0.5045</oasis:entry>
         <oasis:entry colname="col4">0.5066</oasis:entry>
         <oasis:entry colname="col5">0.5420</oasis:entry>
         <oasis:entry colname="col6">0.4226</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DS3</oasis:entry>
         <oasis:entry colname="col3">1.1855</oasis:entry>
         <oasis:entry colname="col4">0.5066</oasis:entry>
         <oasis:entry colname="col5">1.2110</oasis:entry>
         <oasis:entry colname="col6">0.4226</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DS4</oasis:entry>
         <oasis:entry colname="col3">1.6588</oasis:entry>
         <oasis:entry colname="col4">0.5066</oasis:entry>
         <oasis:entry colname="col5">1.6628</oasis:entry>
         <oasis:entry colname="col6">0.4226</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Longitudinal</oasis:entry>
         <oasis:entry colname="col2">DS1</oasis:entry>
         <oasis:entry colname="col3">0.2213</oasis:entry>
         <oasis:entry colname="col4">0.4429</oasis:entry>
         <oasis:entry colname="col5">0.2412</oasis:entry>
         <oasis:entry colname="col6">0.3885</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DS2</oasis:entry>
         <oasis:entry colname="col3">0.5260</oasis:entry>
         <oasis:entry colname="col4">0.4429</oasis:entry>
         <oasis:entry colname="col5">0.5506</oasis:entry>
         <oasis:entry colname="col6">0.3885</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DS3</oasis:entry>
         <oasis:entry colname="col3">1.0873</oasis:entry>
         <oasis:entry colname="col4">0.4429</oasis:entry>
         <oasis:entry colname="col5">1.1000</oasis:entry>
         <oasis:entry colname="col6">0.3885</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DS4</oasis:entry>
         <oasis:entry colname="col3">1.4428</oasis:entry>
         <oasis:entry colname="col4">0.4429</oasis:entry>
         <oasis:entry colname="col5">1.4552</oasis:entry>
         <oasis:entry colname="col6">0.3885</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e4333">The same two-dimensional models are analysed by means of a cloud analysis
(Jalayer and Cornell, 2009), which consists of a series of non-linear time
history analyses considering a large database of unscaled ground-motion
records. For this application, the SIMBAD database (Selected Input Motions
for displacement-Based Assessment and Design,
Smerzini et al., 2014) is adopted. SIMBAD includes 467 tri-axial
accelerograms, generated by 130 worldwide seismic events (shallow crustal
earthquakes with moment magnitudes ranging from 5 to 7.3 and epicentral
distances ranging up to 35 km). A subset of 150 records is considered here
to provide a statistically significant number of strong-motion records of
engineering relevance for the applications presented in this paper. As in
Rossetto et al. (2016), these records are selected by first ranking the 467
records in terms of their PGA values (by using the geometric mean of the two
horizontal components) and then (arbitrarily) keeping the component with the
largest PGA value (for the 150 stations with highest mean PGA). This record
selection strategy is compatible with the adopted cloud analysis procedure
and with the lack of specific, freely available, ground-motion databases for
the considered case-study region. A rigorous site-specific,
hazard-consistent record selection could be used for alternative non-linear
demand estimation methods for probability-based seismic risk assessment
(Jalayer and Cornell, 2009), such as multiple-stripe analysis. The models
used for the numerical pushover analysis are also adopted for the cloud
analysis. The hysteretic behaviour of beams and columns is characterised be
the revised Takeda model (Saiidi and Sozen, 1979), with the columns having a
thinner loop. On the other hand, the hysteretic behaviour of the beam–column
joints is modelled using the modified Sina model (Saiidi and Sozen, 1979),
which is able to capture their pinching behaviour.</p>
      <p id="d1e4336">The results of the dynamic analyses (150 non-linear time history simulations
for each of the four models) are used to plot a cloud of points in the
plane inter-storey drift (chosen as the engineering demand parameter, EDP) vs.
pseudo-spectral acceleration at the first fundamental period (<inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) of
each frame and for a 5 % damping, i.e. <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>(<inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), chosen as
the intensity measure, IM. The linear least-squares method is applied on those
pairs in order to estimate the conditional mean and standard deviation of
EDP given IM and to derive the commonly used power-law model <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:mi mathvariant="normal">EDP</mml:mi><mml:mo>=</mml:mo><mml:mi>a</mml:mi><mml:msup><mml:mi mathvariant="normal">IM</mml:mi><mml:mi>b</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula>,
where <inline-formula><mml:math id="M122" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M123" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> are the parameters of the regression. The derived<?pagebreak page1383?> probabilistic
seismic demand model is used to define a set of four fragility curves, one
for each DS. Such curves are represented in the form of Eq. (2) but using <inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>(<inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) as the intensity measure
of the earthquake intensity. An average fundamental period (given the actual
periods in Fig. 11), equal to 0.5 s, is chosen as
a representative period of the considering building class. Although this
might cause a small decrease in the efficiency of the IM (e.g. Minas and
Galasso, 2019), such a choice allows for a comparison between the different
fragility curves for different buildings. This curve represents the
probability of exceeding a given threshold of inter-storey drift threshold
(corresponding to a given DS), conditioned on a value of the earthquake IM.
Figure 12 represents the fragility curves for the
pre-2012 and post-2012 archetype structures, both for the longitudinal and
transverse directions. The adopted inter-storey drift thresholds are defined
according to the definitions in Kircher et al. (2006) by post processing the
results of the pushover analyses. Those are equal to 0.25 %, 0.6 %,
1.25 % and 1.67 % respectively for DS1, DS2, DS3 and DS4. Such values
are consistent with the highlighted displacements in
Fig. 11 and respectively correspond to the
cracking in the first member in the system, the full onset of the plastic
mechanism, and the attainment of 75 % and 100 % of the ultimate drift in the
first member.</p>
      <?pagebreak page1384?><p id="d1e4426">The results show that the seismic fragility of the post-2012 structures is
reduced with respect to the pre-2012 ones (Table 8). On average, the fragility median of the post-2012 frames are 5.6 %
and 4.3 % higher than the pre-2012 ones, respectively in the transverse
and longitudinal directions. The related dispersion is reduced, on average,
by 16.1 % and 14.3 % for transverse and longitudinal directions.</p>
      <p id="d1e4429"><?xmltex \hack{\newpage}?>It is worth noting that the structure-specific fragilities obtained with the
analyses presented herein could be used to redefine the
INSPIRE index. However, this would require the derivation of numerical
fragility curves for a much larger set of archetype buildings, consistently
with the building typologies identified in Table 1.
In the authors' opinion, adopting the refined fragilities as an input for the INSPIRE index
definition would be inappropriate. Indeed, the proposed index is defined as
a quick and practical tool for seismic vulnerability prioritisation of large
building portfolios (level 1 analysis). A more time-consuming fragility
analysis (level 2) should instead be used to derive quantitative seismic
risk estimates for one or more selected building in the database and to
design structure-specific risk-mitigation strategies (e.g. structural
retrofitting).</p>
</sec>
</sec>
<sec id="Ch1.S5" sec-type="conclusions">
  <label>5</label><title>Concluding remarks</title>
      <p id="d1e4442">This paper introduces the INSPIRE index, which is an empirical proxy for the
relative seismic risk of buildings within a given building portfolio and
allows us to define prioritisation schemes for risk-mitigation measures. The
definition of such an index represents the first step of the wider framework of
the Indonesia School Programme to Increase Resilience (INSPIRE), which aims to develop an advanced, harmonised and
science-based risk assessment framework for school infrastructure in
Indonesia subjected to cascading earthquake–tsunami hazards.</p>
      <p id="d1e4445">To this aim, a data collection form used for the rapid visual inspection of
RC buildings is first developed and presented. Such a form allows one to calculate
the INSPIRE seismic risk prioritisation index and the tsunami PTVA index (in
any of its variations), to obtain a level of geometrical and mechanical
information sufficient to define one or more archetype buildings
(representative of the portfolio) and/or to build refined numerical models,
provided that the simulated design is adopted to cross-check the available
information.</p>
      <p id="d1e4448">The INSPIRE index is specifically calibrated for RC buildings, and consists
of two parts: a baseline score and a performance modifier. The baseline
score is based on the HAZUS MH4 fragility curves, while the performance
modifier is based on the score of the building with regard to eight
secondary parameters, which, if present, are deemed to jeopardise the
building performance. To minimise subjectivity, the relative weight of the
secondary parameters is defined according to the analytic hierarchy process.
This allows us to have a rational and mathematically consistent assignment of
the weights, which is based on pairwise comparisons between the secondary
parameters and eigenvalues theory.</p>
      <p id="d1e4451">The INSPIRE form and seismic risk prioritisation index are adopted for the
analysis of 85 RC school buildings in the city of Banda Aceh, Indonesia,
which is located on the island of Sumatra, the area most affected by the 2004
Indian Ocean earthquake–tsunami sequence. The joint<?pagebreak page1385?> application of the
INSPIRE seismic risk prioritisation index and the PTVA tsunami index allow
one to define a clear and transparent rationale for any prioritisation
schemes for school buildings in Banda Aceh. In fact, the relative seismic
risk of the considered buildings is particularly similar, while the relative
tsunami risk shows a strong dependence with the distance from the coast.
Indeed, the results show that a multi-hazard-based priority list is mostly
governed by the tsunami risk for the case-study portfolio.</p>
      <p id="d1e4455">The advantages of using the INSPIRE form are further demonstrated by
defining two archetype buildings, representative of the portfolio, based on
the RVS results. The seismic performance of the archetype buildings is
firstly analysed by means of non-linear static analyses, both analytically
using the simple lateral mechanism analysis (SLaMA) method and numerically using
refined finite-element models. Finally, the archetypes are analysed by means
of cloud analysis, performing non-linear dynamic analyses using 150 unscaled
natural ground motions and deriving fragility curves.</p>
      <p id="d1e4458">The results in this paper demonstrate the effectiveness of both the INSPIRE
RVS form and INSPIRE seismic risk prioritisation index in providing a
rational method to derive a prioritisation scheme, which can be extended
including multi-hazard considerations, and in allowing the definition of an
archetype building for more detailed evaluations/analyses.</p>
      <p id="d1e4461">This study represents a first step toward a comprehensive framework for
earthquake and tsunami vulnerability and risk assessment and the selection
of optimal retrofitting strategies for school facilities in Indonesia,
through a to a multi-criteria decision-making analysis. Future research will
investigate the numerically based tsunami fragility of the archetype
buildings adopting different approaches (e.g. Petrone et al., 2017) and a
full seismic loss analysis considering non-structural components, which
often represent the highest share of the seismic losses.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e4468">Data will be made available on request.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e4474">RG and CG conceived and designed the study, developed the proposed framework and wrote the manuscript; RG performed the analyses; RG, YI and IR collected the data with EM supervising the data collection; all the authors discussed the results.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e4480">The authors declare that they have no conflict of interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e4486">This study was performed in the framework of the INSPIRE (Indonesia School Programme to Increase Resilience) and i-RESIST (Increasing REsilience of Schools in Indonesia to earthquake Shaking and Tsunami) projects,
funded by the British Council through the Newton Institutional Links scheme
and Research England through the University College London (UCL) Global
Challenges Research Fund (GCRF) Small Research Grants scheme.</p><p id="d1e4488">The Tsunami and Disaster Mitigation Research Centre (TDMRC) at Syiah Kuala
University is acknowledged for the technical support during the field work.
Peter Sammonds,  Karim Aljawhari and Nurmalahayati Nurdin from UCL
are gratefully acknowledged for helping in planning and executing the data
collection.  Rifqi Irvansyah,  Putri Istiqamah,  Sausan Zahrah,
Natasya Amalia, Fajarul Aulia and Ilham M. Siddiq are gratefully
acknowledged for their help in the data collection.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e4493">This research has been supported by the
British Council (Newton Institutional Links) and Research
England (UCL Global Challenges Research Fund Small Research Grants).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e4499">This paper was edited by Maria Ana Baptista
and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Angeletti, P., Bellina, A., Guagenti, E., Moretti, A., and Petrini, V.:
Comparison between vulnerability assessment and damage index, Proceedings
of the Ninth World Conference on Earthquake Engineering, Tokyo-Kyoto, Japan, 181–186, 1988.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
ASCE (American Society of Civil Engineers): Minimum Design Loads for
Buildings and Other Structures, ASCE/SEI Standard 7–10,  Reston, Virginia,
USA, 2010.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
ATC (Applied Technology Council): Tentative Provisions for the
Development of Seismic Regulations for Buildings, Report No. ATC 3-06, Applied Technology
Council, Redwood City, California, 1978.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>
BSN (Badan Standarisasi Nasional): SKBI 1.3.53.1987, Pedoman perencanaan
pembebanan untuk rumah dan gedung, Jackarta, Indonesia,
1987 (in Indonesian).</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>BSN (Badan Standarisasi Nasional): SNI 1726:2002, Standar perencanaan ketahanan
gempa untuk struktur bangunan Gedung, Jackarta, Indonesia,
2002 (in Indonesian).
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
BSN (Badan Standarisasi Nasional): SNI 1726:2012, Tata cara perencanaan ketahanan
gempa unktuk struktur bangunan gedung dan non gedung,
Jackarta, Indonesia, 2012   (in Indonesian).</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
BAPPENAS (Ministry of National Development Planning): Indonesia: Preliminary Damage and Loss
Assessment, The December 26, 2004 Natural Disaster,   Indonesia,
2006.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>Benedetti,  D. and  Petrini, V.: Sulla vulnerabilitaÌ sismica di edifici in
muratura: proposte di un metodo di valutazione, <italic>L'Industria delle Costruzioni</italic>, 149,  66–74,
1984 (in Italian).</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Brzev, S., Scawthorn, C., Charleson, A. W., Allen, L., Greene, M., Jaiswal, K., and  Silva, V.:
GEM Building Taxonomy Version 2.0, GEM Technical Report, GEM Foundation, Pavia, Italy, 2013.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Carr, A. J.: RUAUMOKO2D – The Maori God of Volcanoes and Earthquakes,  Inelastic Analysis
Finite Element program,  Carr research ltd, Christchurch, New Zealand, 2016.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Caterino, N., Iervolino, I., Manfredi, G., and Cosenza, E.: Multi-criteria
decision making for seismic retrofitting of RC structures,  J. Earthq. Eng.,  12, 555–583, 2008.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>
Dall'Osso, F., Dominey-Howes, D., Tarbotton, C., Summerhayes, G., and
Withycombe, G.: Revision and improvement of the PTVA-3 model for assessing
tsunami building vulnerability using “international expert judgement”:
introducing the PTVA-4 model, Nat. Hazards, 83, 1229–1256, 2016.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>
De Luca, F., Woods, G. E. D., Galasso, C.,  and D'Ayala, D.: RC infilled
building performance against the evidence of the 2016 EEFIT Central Italy
post-earthquake reconnaissance mission: empirical fragilities and comparison
with the FAST method,  B. Earthq. Eng.,  16,  2943–2969, 2018.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
Department of Education – State of Alaska: Guide for School Facility
Condition Surveys, Internal Report, Juneau, Alaska, 1997.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Dhungel,  R., Guragain,  R., Joshi,  N., Pradhan,  D., and Acharya,  S. P.: Seismic
Vulnerability Assessment of Public School Buildings in Nawalparasi and
Lamjung District of Nepal, 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 2012.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
CEN (European Comittee for Standardisation): Eurocode 8: Design of
structures for earth-quake resistance,  Part 3: Strengthening and repair of
buildings,  Brussels, 2004.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Elnashai, A. S. and Di Sarno, L.: Fundamentals of earthquake engineering,
Wiley, Toronto, Canada, 2008.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
FEMA P-154: Rapid Visual Screening of Buildings for Potential Seismic
Hazards: A Handbook, 3rd Edition,  Federal Emergency Management Agency,
Washington, DC, 2015.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
FEMA P-155: Rapid Visual Screening of Buildings for Potential Seismic
Hazards: Supporting Documentation, 3rd Edition,  Federal Emergency Management
Agency, Washington, DC, 2015.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>
GADRRRES:  Comprehensive school safety framework,
A global framework in support of the Global Alliance for
Disaster Risk Reduction and Resilience in the education sector
and the worldwide initiative for safe schools,  Preparation for
the 3rd U.N. World Conference on Disaster
Risk Reduction, 2017.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>Gentile, R.: RC Section Rect – practical manual,  Free internal report and
software, available at: <uri>https://www.robertogentile.org/</uri> (last
access: 21 Jun 2019), 2017.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>Gentile, R., Del Vecchio, C., Pampanin, S., Raffaele, D., and  Uva, G.:
Refinement and validation of the Simple Lateral Mechanism Analysis (SLaMA)
procedure for RC bare frames, J. Earthq. Eng.,   <ext-link xlink:href="https://doi.org/10.1080/13632469.2018.1560377" ext-link-type="DOI">10.1080/13632469.2018.1560377</ext-link>, in press, 2019a.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>Gentile, R., Pampanin, S., Raffaele, D., and Uva, G.: Non-linear analysis of RC
masonry-infilled frames using the SLaMA method,  Part 1: mechanical
interpretation of the infill/frame interaction and formulation of the
procedure, B. Earthq. Eng., 17, 3283–3304,  <ext-link xlink:href="https://doi.org/10.1007/s10518-019-00580-w" ext-link-type="DOI">10.1007/s10518-019-00580-w</ext-link>, 2019b.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>Gentile, R., Pampanin, S., Raffaele, D., and Uva, G.: Non-linear analysis of RC
masonry-infilled frames using the SLaMA method,  Part 2: parametric analysis
and validation of the procedure, B. Earthq. Eng., 17, 3305–3326,   <ext-link xlink:href="https://doi.org/10.1007/s10518-019-00584-6" ext-link-type="DOI">10.1007/s10518-019-00584-6</ext-link>, 2019c.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>Gentile, R., Pampanin, S., Raffaele, D., and Uva, G.: Analytical seismic
assessment of RC dual wall/frame systems using SLaMA: Proposal and
validation,  Eng. Struct., 188,  493–505,  <ext-link xlink:href="https://doi.org/10.1016/j.engstruct.2019.03.029" ext-link-type="DOI">10.1016/j.engstruct.2019.03.029</ext-link>, 2019d.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>
Giovinazzi, S. and  Lagomarsino, S.: A macroseismic model for the vulnerability
assessment of buildings,  Proc. 13th world conference on earthquake
engineering,  Vancouver, Canada, 2004.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Grant, D. N., Bommer, J. J., Pinho, R., Calvi, G. M., Goretti, A., and Meroni, F.:
A Prioritization Scheme for Seismic Intervention in School Buildings in
Italy,  Earthq. Spectra, 23,  291–314, 2007.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>
Grimaz, S., Meroni, F., Petrini, V., Tomasoni, R., and Zonno, G.: Il ruolo
dei dati di dan- neggiamento del terremoto del Friuli, nello studio di
modelli di vulnerabilitaÌ sismica degli edifici in muratura,  Proceedings of
the Conference on “La scienza e i terremoti-Analisi e prospettive dall'esperienza
del Friuli-1976/1996”, Udine, Italy, 89–96,
1996.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>
ICBO (International Conference of Buildings Officials): Uniform Building
Code,  Whittier, California, USA, 1994.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
ICBO (International Conference of Buildings Officials): Uniform Building
Code,  Whittier, California, USA, 1997.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
Iemura, H., Pradono, M. H., Sugimoto, M., Takahashi, Y., and Husen, A.:
Tsunami height memorial poles in banda aceh and recommendations for disaster
prevention,
Proceedings of the International Symposium on Engineering Lessons
Learned from the 2011 Great East Japan Earthquake, 1–4 March,  Tokyo, Japan, 2012.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>ISTAT (Istituto nazionale di STATistica): 15th general census of
population and housing, available at: <uri>http://dati-censimentopopolazione.istat.it</uri> (last
access: 21 Jun 2019), 2011 (in Italian).</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Jalayer, F. and Cornell, C. A.: Alternative non-linear demand estimation
methods for probability-base seismic assessments, Earthq. Eng. Struct. D., 38, 951–972, 2009.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>
Kircher, C. A., Whitman, R. V., and Holmes, W. T.: HAZUS Earthquake Loss Estimation
Methods, Nat. Hazards Rev., 7, 45–59, 2006.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>
Magenes, G. and Pampanin, S.: Seismic response of gravity-load design frames
with masonry infills, 13th World Conference on Earthquake Engineering, Vancouver, British Columbia, Canada,  2004.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>
Minas, S. and Galasso, C.: Accounting for spectral shape in simplified
fragility analysis of reinforced concrete buildings, Soil Dynamics and
Earthquake Engineering, 119, 91–103,  2019.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>
Montejo, L. A. and Kowalsky, M. J.:  Set of codes for the analysis of reinforced concrete
members, Raleigh, North Carolina, 2007.</mixed-citation></ref>
      <?pagebreak page1387?><ref id="bib1.bib38"><label>38</label><mixed-citation>
Nassirpour, A., Galasso, C., and D'Ayala, D.: Multi-Hazard Physical Vulnerability
Prioritization of School Infrastructure in the Philippines,  11th US
National Conference on Earthquake Engineering (11NCEE),  Los Angeles, CA,
USA, 25–29 June 2018.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>
NZSEE: New Zealand Society for Earthquake Engineering, The seismic
assessment of existing buildings – technical guidelines for engineering
assessments, Wellington, New Zealand, 2017.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>
Palermo, A., Liu, R., Rais, A., McHaffie, B., Andisheh, K., Pampanin, S., Gentile,
R., Nuzzo, I., Graniero, M., Loporcaro, G., McGann, C., and Wotherspoon, L.:
Performance of road bridges during the 14th November 2016 Kaikoura
earthquake,  Bulletin of the New Zealand Society for Earthquake Engineering, 50,  253–270, 2017.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><mixed-citation>
Paulay, T. and Priestley, M. J. N.: Seismic design of reinforced concrete
and masonry buildings, Wiley, New York, 1992.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
Pazzi, V., Morelli, S., Pratesi, F., Sodi, T., Valori, L., Gambacciani, L.,
and Casagli, N.: Assessing the safety of schools affected by geo-hydrologic
hazards: The geohazard safety classification (GSC),  Int. J. Disast. Risk Re., 15,  80–93, 2016.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation>
Pescaroli, G. and Alexander, D.: Critical infrastructure, panarchies and the
vulnerability paths of cascading disasters, Natural Hazards, 82,
175–192, 2016.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation>
Petrone, C., Goda, K., and Rossetto, T.: Fragility assessment of a RC structure
under tsunami actions via nonlinear static and dynamic analyses,  Eng.
Struct., 136,  36–53, 2017.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>
Pomonis, A., Rossetto, T., Peiris, N., Wilkinson, S., Del Re, D., Koo, R.,
Manlapig, R., and Gallocher, S.: The Indian Ocean Tsunami of 26 December 2004:
Mission Findings in Sri Lanka and Thailand,  Earthquake Engineering Field
Investigation Team report, 2006.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>
Priestley, M. J. N., Calvi, G. M., and Kowalsky, M. J.: Displacement-based
seismic design of structures, IUSS Press, Pavia,
Italy, 2007.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation>Rossetto, T., Gehl, P., Minas, S., Galasso, C., Duffour, P., Douglas, J., and
Cook, O.: FRACAS: A capacity spectrum approach for seismic fragility
assessment including record-to-record variability,  Eng. Struct.,
125, 337–348, 2016.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib48"><label>48</label><mixed-citation>
Saaty, T. L.: The analytical hierarchy process: Planning, priority setting,
resource allocation, London, McGraw-Hill, 1980.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><mixed-citation>
Saiidi, M. and Sozen, M.: Simple and complex models for nonlinear seismic
response of reinforced concrete structures, Technical Report Report No. 465,
University of Illinois, Urbana, Illinois, USA, 1979.</mixed-citation></ref>
      <ref id="bib1.bib50"><label>50</label><mixed-citation>
Seta, W. J.: Atlas Lengkap Indonesia dan Dunia (untuk SD, SMP, SMU, dan
Umum),  Pustaka Widyatama,  p. 7, 2000.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><mixed-citation>
Sharpe, R. D.: The Seismic Response of Inelastic Structures,
PhD thesis, Department of Civil Engineering, University of
Canterbury, Christchurch, New Zealand, 1976.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><mixed-citation>
Smerzini, C., Galasso, C., Iervolino, I., and Paolucci, R.: Ground motion
record selection based on broadband spectral compatibility, Earthq. Spectra, 30,  1427–1448, 2014.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><mixed-citation>Stephenson, V. and D'Ayala, D.: A new approach to flood vulnerability assessment for historic buildings in England, Nat. Hazards Earth Syst. Sci., 14, 1035–1048, <ext-link xlink:href="https://doi.org/10.5194/nhess-14-1035-2014" ext-link-type="DOI">10.5194/nhess-14-1035-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><mixed-citation>
UNCRD (United Nations Centre for Regional Development): Reducing
vulnerability of school children to earthquakes,  UNCDR report, 2009.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><mixed-citation>
Uva, G., Sanjust, C. A., Casolo, S., and Mezzina, M.: ANTAEUS Project for the
Regional Vulnerability Assessment of the Current Building Stock in
Historical Centers,  Int. J. Archit. Herit., 10,
20–43, 2016.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><mixed-citation>
Womble,  J. A., Wood,  R. L., Eguchi, R. T., Ghosh,  S., and Mohammadi, M. E.: Current
methods and future advances for rapid, remote-sensing-based wind damage
assessment, Resilient Infrastructure, London, UK, 2016.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><mixed-citation>
Zhou, L., Galasso, C., and D'Ayala, D.: CROSSH – China Resilience of Schools to
Seismic Hazard: a case study in Beichuan Qiang Autonomous County, Sichuan,
11th National Conference on Earthquake Engineering (11NCEE), Los Angeles,
CA, USA, 25–29 June 2018.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>From rapid visual survey to multi-hazard risk prioritisation and numerical fragility of school buildings</article-title-html>
<abstract-html><p>Regional seismic risk assessment is paramount in
earthquake-prone areas, for instance, to define and implement prioritisation
schemes for earthquake risk reduction. As part of the Indonesia School Programme to Increase Resilience (INSPIRE), this paper
proposes an ad hoc rapid-visual-survey form, allowing one to (1) calculate the
newly proposed INSPIRE seismic risk prioritisation index, which is an
empirical proxy for the relative seismic risk of reinforced concrete (RC)
buildings within a given building portfolio; (2) calculate the Papathoma
Tsunami Vulnerability Assessment (PTVA) index, in any of its variations; (3) define one or more archetype buildings representative of the analysed
portfolio; (4) derive detailed numerical models of the archetype buildings,
provided that the simulated design is used to cross-check the model assumptions.
The proposed INSPIRE index combines a baseline score, calibrated based on
fragility curves, and a performance modifier, calibrated through the
analytic hierarchy process (AHP) to minimise subjectivity. An attempt to
define a multi-hazard prioritisation scheme is proposed, combining the
INSPIRE and PTVA indices. Such a multi-level framework is implemented for 85
RC school buildings in Banda Aceh, Indonesia, the most affected city by
the 2004 Indian Ocean earthquake–tsunami sequence. As part of the proposed
framework, two archetype buildings representative of the entire portfolio
are defined based on the collected data. Their seismic performance is
analysed by means of non-linear static analyses, using both the analytical
simple lateral mechanism analysis (SLaMA) method and numerical finite-element pushover analyses to investigate the expected plastic mechanisms and
derive displacement/drift thresholds to define appropriate damage states.
Finally, non-linear dynamic analyses are performed to derive fragility
curves for the archetype buildings. This paper demonstrates the
effectiveness of the INSPIRE data collection form and proposed index in
providing a rational method to derive seismic risk prioritisation schemes
and in allowing the definition of archetype buildings for more detailed
evaluations/analyses.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Angeletti, P., Bellina, A., Guagenti, E., Moretti, A., and Petrini, V.:
Comparison between vulnerability assessment and damage index, Proceedings
of the Ninth World Conference on Earthquake Engineering, Tokyo-Kyoto, Japan, 181–186, 1988.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
ASCE (American Society of Civil Engineers): Minimum Design Loads for
Buildings and Other Structures, ASCE/SEI Standard 7–10,  Reston, Virginia,
USA, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
ATC (Applied Technology Council): Tentative Provisions for the
Development of Seismic Regulations for Buildings, Report No. ATC 3-06, Applied Technology
Council, Redwood City, California, 1978.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
BSN (Badan Standarisasi Nasional): SKBI 1.3.53.1987, Pedoman perencanaan
pembebanan untuk rumah dan gedung, Jackarta, Indonesia,
1987 (in Indonesian).
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
BSN (Badan Standarisasi Nasional): SNI 1726:2002, Standar perencanaan ketahanan
gempa untuk struktur bangunan Gedung, Jackarta, Indonesia,
2002 (in Indonesian).

</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
BSN (Badan Standarisasi Nasional): SNI 1726:2012, Tata cara perencanaan ketahanan
gempa unktuk struktur bangunan gedung dan non gedung,
Jackarta, Indonesia, 2012   (in Indonesian).
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
BAPPENAS (Ministry of National Development Planning): Indonesia: Preliminary Damage and Loss
Assessment, The December 26, 2004 Natural Disaster,   Indonesia,
2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Benedetti,  D. and  Petrini, V.: Sulla vulnerabilitaÌ sismica di edifici in
muratura: proposte di un metodo di valutazione, <i>L'Industria delle Costruzioni</i>, 149,  66–74,
1984 (in Italian).
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Brzev, S., Scawthorn, C., Charleson, A. W., Allen, L., Greene, M., Jaiswal, K., and  Silva, V.:
GEM Building Taxonomy Version 2.0, GEM Technical Report, GEM Foundation, Pavia, Italy, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Carr, A. J.: RUAUMOKO2D – The Maori God of Volcanoes and Earthquakes,  Inelastic Analysis
Finite Element program,  Carr research ltd, Christchurch, New Zealand, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Caterino, N., Iervolino, I., Manfredi, G., and Cosenza, E.: Multi-criteria
decision making for seismic retrofitting of RC structures,  J. Earthq. Eng.,  12, 555–583, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Dall'Osso, F., Dominey-Howes, D., Tarbotton, C., Summerhayes, G., and
Withycombe, G.: Revision and improvement of the PTVA-3 model for assessing
tsunami building vulnerability using “international expert judgement”:
introducing the PTVA-4 model, Nat. Hazards, 83, 1229–1256, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
De Luca, F., Woods, G. E. D., Galasso, C.,  and D'Ayala, D.: RC infilled
building performance against the evidence of the 2016 EEFIT Central Italy
post-earthquake reconnaissance mission: empirical fragilities and comparison
with the FAST method,  B. Earthq. Eng.,  16,  2943–2969, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Department of Education – State of Alaska: Guide for School Facility
Condition Surveys, Internal Report, Juneau, Alaska, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Dhungel,  R., Guragain,  R., Joshi,  N., Pradhan,  D., and Acharya,  S. P.: Seismic
Vulnerability Assessment of Public School Buildings in Nawalparasi and
Lamjung District of Nepal, 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
CEN (European Comittee for Standardisation): Eurocode 8: Design of
structures for earth-quake resistance,  Part 3: Strengthening and repair of
buildings,  Brussels, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Elnashai, A. S. and Di Sarno, L.: Fundamentals of earthquake engineering,
Wiley, Toronto, Canada, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
FEMA P-154: Rapid Visual Screening of Buildings for Potential Seismic
Hazards: A Handbook, 3rd Edition,  Federal Emergency Management Agency,
Washington, DC, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
FEMA P-155: Rapid Visual Screening of Buildings for Potential Seismic
Hazards: Supporting Documentation, 3rd Edition,  Federal Emergency Management
Agency, Washington, DC, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
GADRRRES:  Comprehensive school safety framework,
A global framework in support of the Global Alliance for
Disaster Risk Reduction and Resilience in the education sector
and the worldwide initiative for safe schools,  Preparation for
the 3rd U.N. World Conference on Disaster
Risk Reduction, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Gentile, R.: RC Section Rect – practical manual,  Free internal report and
software, available at: <a href="https://www.robertogentile.org/" target="_blank">https://www.robertogentile.org/</a> (last
access: 21 Jun 2019), 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Gentile, R., Del Vecchio, C., Pampanin, S., Raffaele, D., and  Uva, G.:
Refinement and validation of the Simple Lateral Mechanism Analysis (SLaMA)
procedure for RC bare frames, J. Earthq. Eng.,   <a href="https://doi.org/10.1080/13632469.2018.1560377" target="_blank">https://doi.org/10.1080/13632469.2018.1560377</a>, in press, 2019a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Gentile, R., Pampanin, S., Raffaele, D., and Uva, G.: Non-linear analysis of RC
masonry-infilled frames using the SLaMA method,  Part 1: mechanical
interpretation of the infill/frame interaction and formulation of the
procedure, B. Earthq. Eng., 17, 3283–3304,  <a href="https://doi.org/10.1007/s10518-019-00580-w" target="_blank">https://doi.org/10.1007/s10518-019-00580-w</a>, 2019b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Gentile, R., Pampanin, S., Raffaele, D., and Uva, G.: Non-linear analysis of RC
masonry-infilled frames using the SLaMA method,  Part 2: parametric analysis
and validation of the procedure, B. Earthq. Eng., 17, 3305–3326,   <a href="https://doi.org/10.1007/s10518-019-00584-6" target="_blank">https://doi.org/10.1007/s10518-019-00584-6</a>, 2019c.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Gentile, R., Pampanin, S., Raffaele, D., and Uva, G.: Analytical seismic
assessment of RC dual wall/frame systems using SLaMA: Proposal and
validation,  Eng. Struct., 188,  493–505,  <a href="https://doi.org/10.1016/j.engstruct.2019.03.029" target="_blank">https://doi.org/10.1016/j.engstruct.2019.03.029</a>, 2019d.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Giovinazzi, S. and  Lagomarsino, S.: A macroseismic model for the vulnerability
assessment of buildings,  Proc. 13th world conference on earthquake
engineering,  Vancouver, Canada, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Grant, D. N., Bommer, J. J., Pinho, R., Calvi, G. M., Goretti, A., and Meroni, F.:
A Prioritization Scheme for Seismic Intervention in School Buildings in
Italy,  Earthq. Spectra, 23,  291–314, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Grimaz, S., Meroni, F., Petrini, V., Tomasoni, R., and Zonno, G.: Il ruolo
dei dati di dan- neggiamento del terremoto del Friuli, nello studio di
modelli di vulnerabilitaÌ sismica degli edifici in muratura,  Proceedings of
the Conference on “La scienza e i terremoti-Analisi e prospettive dall'esperienza
del Friuli-1976/1996”, Udine, Italy, 89–96,
1996.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
ICBO (International Conference of Buildings Officials): Uniform Building
Code,  Whittier, California, USA, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
ICBO (International Conference of Buildings Officials): Uniform Building
Code,  Whittier, California, USA, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Iemura, H., Pradono, M. H., Sugimoto, M., Takahashi, Y., and Husen, A.:
Tsunami height memorial poles in banda aceh and recommendations for disaster
prevention,
Proceedings of the International Symposium on Engineering Lessons
Learned from the 2011 Great East Japan Earthquake, 1–4 March,  Tokyo, Japan, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
ISTAT (Istituto nazionale di STATistica): 15th general census of
population and housing, available at: <a href="http://dati-censimentopopolazione.istat.it" target="_blank">http://dati-censimentopopolazione.istat.it</a> (last
access: 21 Jun 2019), 2011 (in Italian).
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Jalayer, F. and Cornell, C. A.: Alternative non-linear demand estimation
methods for probability-base seismic assessments, Earthq. Eng. Struct. D., 38, 951–972, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Kircher, C. A., Whitman, R. V., and Holmes, W. T.: HAZUS Earthquake Loss Estimation
Methods, Nat. Hazards Rev., 7, 45–59, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Magenes, G. and Pampanin, S.: Seismic response of gravity-load design frames
with masonry infills, 13th World Conference on Earthquake Engineering, Vancouver, British Columbia, Canada,  2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Minas, S. and Galasso, C.: Accounting for spectral shape in simplified
fragility analysis of reinforced concrete buildings, Soil Dynamics and
Earthquake Engineering, 119, 91–103,  2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Montejo, L. A. and Kowalsky, M. J.:  Set of codes for the analysis of reinforced concrete
members, Raleigh, North Carolina, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Nassirpour, A., Galasso, C., and D'Ayala, D.: Multi-Hazard Physical Vulnerability
Prioritization of School Infrastructure in the Philippines,  11th US
National Conference on Earthquake Engineering (11NCEE),  Los Angeles, CA,
USA, 25–29 June 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
NZSEE: New Zealand Society for Earthquake Engineering, The seismic
assessment of existing buildings – technical guidelines for engineering
assessments, Wellington, New Zealand, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Palermo, A., Liu, R., Rais, A., McHaffie, B., Andisheh, K., Pampanin, S., Gentile,
R., Nuzzo, I., Graniero, M., Loporcaro, G., McGann, C., and Wotherspoon, L.:
Performance of road bridges during the 14th November 2016 Kaikoura
earthquake,  Bulletin of the New Zealand Society for Earthquake Engineering, 50,  253–270, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Paulay, T. and Priestley, M. J. N.: Seismic design of reinforced concrete
and masonry buildings, Wiley, New York, 1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Pazzi, V., Morelli, S., Pratesi, F., Sodi, T., Valori, L., Gambacciani, L.,
and Casagli, N.: Assessing the safety of schools affected by geo-hydrologic
hazards: The geohazard safety classification (GSC),  Int. J. Disast. Risk Re., 15,  80–93, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Pescaroli, G. and Alexander, D.: Critical infrastructure, panarchies and the
vulnerability paths of cascading disasters, Natural Hazards, 82,
175–192, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Petrone, C., Goda, K., and Rossetto, T.: Fragility assessment of a RC structure
under tsunami actions via nonlinear static and dynamic analyses,  Eng.
Struct., 136,  36–53, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Pomonis, A., Rossetto, T., Peiris, N., Wilkinson, S., Del Re, D., Koo, R.,
Manlapig, R., and Gallocher, S.: The Indian Ocean Tsunami of 26 December 2004:
Mission Findings in Sri Lanka and Thailand,  Earthquake Engineering Field
Investigation Team report, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Priestley, M. J. N., Calvi, G. M., and Kowalsky, M. J.: Displacement-based
seismic design of structures, IUSS Press, Pavia,
Italy, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Rossetto, T., Gehl, P., Minas, S., Galasso, C., Duffour, P., Douglas, J., and
Cook, O.: FRACAS: A capacity spectrum approach for seismic fragility
assessment including record-to-record variability,  Eng. Struct.,
125, 337–348, 2016.

</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Saaty, T. L.: The analytical hierarchy process: Planning, priority setting,
resource allocation, London, McGraw-Hill, 1980.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Saiidi, M. and Sozen, M.: Simple and complex models for nonlinear seismic
response of reinforced concrete structures, Technical Report Report No. 465,
University of Illinois, Urbana, Illinois, USA, 1979.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Seta, W. J.: Atlas Lengkap Indonesia dan Dunia (untuk SD, SMP, SMU, dan
Umum),  Pustaka Widyatama,  p. 7, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Sharpe, R. D.: The Seismic Response of Inelastic Structures,
PhD thesis, Department of Civil Engineering, University of
Canterbury, Christchurch, New Zealand, 1976.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
Smerzini, C., Galasso, C., Iervolino, I., and Paolucci, R.: Ground motion
record selection based on broadband spectral compatibility, Earthq. Spectra, 30,  1427–1448, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
Stephenson, V. and D'Ayala, D.: A new approach to flood vulnerability assessment for historic buildings in England, Nat. Hazards Earth Syst. Sci., 14, 1035–1048, <a href="https://doi.org/10.5194/nhess-14-1035-2014" target="_blank">https://doi.org/10.5194/nhess-14-1035-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
UNCRD (United Nations Centre for Regional Development): Reducing
vulnerability of school children to earthquakes,  UNCDR report, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
Uva, G., Sanjust, C. A., Casolo, S., and Mezzina, M.: ANTAEUS Project for the
Regional Vulnerability Assessment of the Current Building Stock in
Historical Centers,  Int. J. Archit. Herit., 10,
20–43, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
Womble,  J. A., Wood,  R. L., Eguchi, R. T., Ghosh,  S., and Mohammadi, M. E.: Current
methods and future advances for rapid, remote-sensing-based wind damage
assessment, Resilient Infrastructure, London, UK, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Zhou, L., Galasso, C., and D'Ayala, D.: CROSSH – China Resilience of Schools to
Seismic Hazard: a case study in Beichuan Qiang Autonomous County, Sichuan,
11th National Conference on Earthquake Engineering (11NCEE), Los Angeles,
CA, USA, 25–29 June 2018.
</mixed-citation></ref-html>--></article>